CMM-40
– USER MANUAL
71
h)
Crest factor ................................................................ ≤3 at full scale up to 500V
...........................................................................decreasing linearly to ≤1,5 at 1000V
i)
PEAK ............................................................................... captures peaks >1ms
j)
Measurements rate.................................................2 times per second, nominal
k)
Input impedance .......................................................>10MΩ VDC & >9MΩ VAC
l)
Display .....................................40,000 count backlit liquid crystal with bargraph
m)
Store capacitance ........................................................................................ 2000
n)
Size .......................................................................................... 187 x 81 x 55mm
o)
Weight (includes holster) ............................................................................. 342g
p)
Fuses ........................................ mA, µA ranges; 0.5A/1000V ceramic fast blow
....................................................................... A range; 10A/1000V ceramic fast blow
q)
Operating temperature ........................................... 0ºC to 40ºC (32ºF to 104ºF)
r)
Storage temperature............................................. -20
o
C to 60
o
C (-4
o
F to 140
o
F)
s)
Operating humidity .................................................. max 80% up to 31ºC (87ºF)
........................................................ decreasing linearly to 50% at 40ºC (104ºF)
t)
Storage humidity ......................................................................................... <80%
u)
Max. operating altitude ............................................................... 2000m (7000ft)
v)
Auto power OFF ................................ 15 minutes (approx.) with disable feature
w)
Enclosure .................................................................. double molded, waterproof
x)
Compliance with the requirements specified in the following standards ............
.......................................................................................................... EN 61010-1
.................................................................................................. EN 61010-2-032
y)
Quality standard ................................................................................... ISO 9001
12.2 Standard equipment
The standard set provided by the manufacturer includes the fol-
lowing components:
The CMM-40 meter,
Test leads (2 pieces),
9V battery,
K Type temperature probe,
Socets protective plugs (2 szt.),
Operating manual,
Carrying case,
Warranty card.
Summary of Contents for CMM-40
Page 1: ...INSTRUKCJA OBS UGI 1 USER MANUAL 39 MANUAL DE USO 73 CMM 40 v1 6 19 10 2018...
Page 2: ......
Page 3: ...1 INSTRUKCJA OBS UGI MULTIMETR PRZEMYS OWY CMM 40 Wersja 1 6 19 10 2018...
Page 41: ...39 USER MANUAL INDUSTRIAL MULTIMETER CMM 40 Version 1 6 19 10 2018...
Page 75: ...73 MANUAL DE USO MULT METRO INDUSTRIAL CMM 40 Versi n 1 6 19 10 2018...
Page 111: ......
Page 112: ......