51
4.3 Test leads
The manufacturer guarantees correct measurement indications
provided original test leads are used.
WARNING:
Connection of inadequate test leads constitutes a risk of
electric shock with a dangerous voltage or may be a cause of
measurement errors.
5
Measurements
It is recommended to get acquainted thoroughly with the con-
tents of the present chapter since it describes the measurement
systems, the manner of realisation of measurements and the basic
principles of interpretation of the results.
5.1 DC voltage measurements
ATTENTION!
Do not measure DC voltages if a motor on the circuit is being
switched ON or OFF. Large voltage surges may occur that
can damage the meter.
In order to realise a measurement of DC voltage, it is necessary
to realise the following actions:
Set the function switch to the
VDC
position,
with the
RANGE
button set the measurement range manually
if necessary,
Insert the black test lead banana plug into the negative
COM
jack. Insert the red test lead banana plug into the positive
V
jack,
Touch the black test probe tip to the negative side of the cir-
cuit. Touch the red test probe tip to the positive side of the cir-
cuit,
Read the voltage in the display,
Having done the measurement disconnect the test leads from
the meter.
Summary of Contents for CMM-40
Page 1: ...INSTRUKCJA OBS UGI 1 USER MANUAL 39 MANUAL DE USO 73 CMM 40 v1 6 19 10 2018...
Page 2: ......
Page 3: ...1 INSTRUKCJA OBS UGI MULTIMETR PRZEMYS OWY CMM 40 Wersja 1 6 19 10 2018...
Page 41: ...39 USER MANUAL INDUSTRIAL MULTIMETER CMM 40 Version 1 6 19 10 2018...
Page 75: ...73 MANUAL DE USO MULT METRO INDUSTRIAL CMM 40 Versi n 1 6 19 10 2018...
Page 111: ......
Page 112: ......