From operation in normal mode with the screen switched on 

(the password must be OFF, value =0)

Press 

ESC

 to enter the probe and relay test menu, continue pressing it until you see that all segments of the screen light up and 

the system returns to normal mode.

ESC

OK

576

Sonder

ESC

OK

576

Sonder

S

E
T

ESC

OK

576

Sonder

S

E
T

%

All the statistical values, parameter settings, function activations and the installation type are reset, but the 
total operation hours of the relays and the megawatts/hours of the calorimeter are not reset.

Press ESC

10      seconds

Keep it pressed for

RESETTING VALUES AND RESTORING FACTORY SETTINGS

FACTORY SETTINGS

SETTINGS

FUNCTIONS

 (all the functions are switched off and there are no factory settings)

Probe calibration (S1…S7):
Tank priority (1…6):
Sequential priority:
Tank cooling (1…6):
Light:
Password: 

0.0 ºC
5.0 ºC

OFF

130 ºC

OFF
OFF

winter

6.0 ºC
2.0 ºC

85 ºC

2.0 ºC

10 ºC
90 ºC

Ambient thermostat 1
Ambient thermostat 2
Anti-frost

SYSTEMS

Double pump
Calorimeter
Tubular sensors

Return increase
Unit heater
OR function
AND function

Independent thermostat 1
Independent thermostat 2
Independent thermostat 3

Regulation mode:
Activation differential:
Deactivation differential:
Tank temperature alarm (1…6):
Temperature differential:
Minimum setting limit:
Maximum setting limit:

Active system:                    

1.1 (1 tank + 1 pump)

If the password is activated it is impossible to reset the values and restore the factory settings. To do so, it is 
necessary first to deactivate the password (value =0) in the settings menu.
If an unauthorised user tries to reset the values, he would press the ESC key for 10 seconds and only be able 
to enter the probe and relay test. When you exit the test, the relays return to their original status.

12

OPERATION

S7

Hot water

R6

R4

R2

S2

R5

S3

S2

S1

S4

POWER SUPPLY

S4 S5 S6

S4

S5

R1

R3

S7

S1

N

L

230 V~ 

50/60 Hz

Hot water

Hot water

Hot water

R6

S6

Hot water

S3

Hot water

MAINS

WATER

R2

R4

R5

R3

R1

MAINS

WATER

MAINS

WATER

MAINS

WATER

MAINS

WATER

MAINS

WATER

Example of  Installation on different floors (up to 6 flats)

For this type, the installation is as follows:

- 1 Allegro 576 per landing. It can control up to 6 apartments per floor. The unit will be installed in the communal area of the 

landing in the fuse box and probe 1 will be installed on the outgoing circuit.

- 1 Allegro 576 installed in the general meter room. In order to control collectors and additional functions such as cooling by 

unit heater, calorimeter, etc.

- If the building has fewer apartments per landing, the resources can be 

used for other landings, or common devices such as the unit heater, 
collectors etc.

BLOCK APARTMENTS

25

1 Allegro 576 per floor

 installed in the junction box of each landing

1 Allegro 576 in the machine room

EXAMPLES

Summary of Contents for Allegro 576 BOX

Page 1: ... Manual Energy control Avenida la Llana Nº 93 P I La Llana 08191 RUBÍ Barcelona Spain Tel 34 93 588 42 11 Fax 34 93 588 49 94 www sonder es info sonder regulacion com SONDER REGULACIÓN S A Allegro 576 RAIL code 20 043 Allegro 576 BOX code 20 054 ...

Page 2: ...5815VØ MAY 09 2 35 NOTES ...

Page 3: ...scription Technical specifications Dimensions Connections Operation Getting started Probe and relay test Screen view Configuration Factory settings and resetting Resource control Menu Statistics Functions Systems Settings 33 4 5 6 6 6 6 7 8 8 9 10 11 12 13 16 16 18 22 26 ...

Page 4: ...modify the product technical data and assembly and use instructions without prior notification WARRANTY CONDITIONS This device has Three year warranty The warranty is limited to the replacement of faulty parts which will be restored to the same condition in which they were received No packaging batteries instructions or any other accessories included with the product will be replaced We cannot acc...

Page 5: ...3 channels 3 alarms Telephone control landline mobile 1 channel 1 alarm Water meter with pulse output L 50mm L 100mm L 200mm Conductive paste for sheaths 5 PRESENTATION Stainless steel sheaths GSM Consult us about models for remote management and data storage with SD card Visit our WEBSITE New products All our products Technical documentation Catalogues www sonder es Consult our wide range of prod...

Page 6: ... has reached 45 the swimming pool is heated to dissipate the excess heat instead of accumulating it in the collectors thus preventing the installation from overheating Example with system 6 2 Accumulator priority ºC AC 1 AC 2 AC 3 65 40 5 H W U H Swimming pool In summer Tank alarm ºC AL 1 AL 2 AL 3 70 45 35 Since the underfloor heating does not need to be activated during the summer its priority c...

Page 7: ...each type of system If they are of use to you the device is ready to control and regulate your installation If due to the needs of your installation you require other settings read this section carefully In the menu you can adjust the parameters that define how the installation will operate default values and setting ranges SETTING RANGE ADJUSTED Adjustment mode Activation differential Deactivatio...

Page 8: ...lthough only 1 symbol is shown on the screen All the settings are preset to factory default values If these values do not suit the needs of your installation consult page 26 to configure them 8 OPERATION ESC OK 576 Sonder Accumulator cooling This parameter allows you to reduce the temperature of the accumulator by recirculating the collector when it detects that the collector temperature is lower ...

Page 9: ...key the system returns to normal operation and the relays return to the status required by the system at that time With the password OFF The system does not exit the test menu until the ESC key is pressed forced manual mode Then move on to the relays forced manual where you can manually activate deactivate each relay Press OK to activate deactivate relay R1 Press to move on to the next relay Press...

Page 10: ...LIGHT TIMER LIGHT parameter OFF 10 ESC OK 576 Sonder This screen informs you that The probe assigned to the radiator has a reading error S S OPERATION SETTINGS 27 Tank temperature alarm This parameter defines a temperature alarm for each accumulator depending on the system a unit heater or cooling system is activated another accumulator is charged or circulation is stopped In the PARÁMETROS menu p...

Page 11: ...to move to PARÁMETROS and then press OK In the menu you can adjust the settings that will define the operation of the installation Winter or summer mode Activation differential Deactivation differential Temperature alarm in tanks 1 to 6 Temperature differential general for all settings Minimum setting limit Maximum setting limit Minimum ambient limit Maximum ambient limit Separate calibration for ...

Page 12: ...limit Maximum setting limit Active system 1 1 1 tank 1 pump If the password is activated it is impossible to reset the values and restore the factory settings To do so it is necessary first to deactivate the password value 0 in the settings menu If an unauthorised user tries to reset the values he would press the ESC key for 10 seconds and only be able to enter the probe and relay test When you ex...

Page 13: ...3 3 1 3 2 3 3 5 1 5 2 5 3 6 1 6 2 6 3 4 1 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 13 OPERATION Hot water S4 S5 R3 S3 R5 R2 S1 S7 R6 A B C D EXCHANGER PURIFIER F R1 R4 S6 E S1 S2 S3 S4 S5 S6 S7 R1 ...

Page 14: ... S S S S S OK S S S S S S S S S S S S S S S S ESC S S S S S S S S S S OPERATION collector array 2 pumps 2 tanks collector array tank swimming pool 2 pumps collector array tank heating 2 pumps collector array 2 tanks pump 3 way valve collector array tank swimming pool pump 3 way valve collector array tank heating return pump 3 way valve 2 collector arrays east and west 2 tanks 2 pumps 3 way valve 2...

Page 15: ...n Use the keys to move on to the next system To confirm the chosen system press OK and press the ESC key to return the previous menu Once the system has been configured the unit saves the changes and returns to normal operation SYSTEMS The representation of the units on these diagrams is symbolic One solar panel means there is one array of solar collectors but when there are 2 it means that there ...

Page 16: ...e solar system you need for your installation and then the functions since you may not be able to configure the rest of the functions according to relays the systems leaves frees MENU Thermostat 1 2 3 independent Thermostat 1 2 ambient Anti frost Double pump alternation Cooling by unit heater Calorimeter Tubular sensor Return increase OR AND Regulates the temperature of a probe heating underfloor ...

Page 17: ...s ESC to return to the FUNCIONES menu This function conditions the status of a relay based on the status of all the selected relays For example if you choose R1 as the slave relay and R2 R4 and R6 as the main relays R1 will be activated when R2 AND R4 AND R6 are activated When any one of the main relays is off the slave relay switches off AND ESC OK 576 FUNCTIONS 20 Press OK to enter the function ...

Page 18: ...to enter the function settings where you can activate deactivate the function and set the total time that each pump will operate before changing 4 to 120 hours Press to change the flashing value and press OK to confirm the selection Press ESC to return to the FUNCIONES menu S S This function allows you to double a pump in your installation so that the two pumps work in alternation Double pump alte...

Reviews: