SAFETY INSTRUCTIONS

- Before installing the Allegro 576 regulator, ensure 

that  the  environmental  conditions  (operating 
temperature, humidity, pollution and gas emissions) 
are suitable, as any of these factors can cause the 
unit to malfunction.

- When handling the Allegro 576 regulator, whether 

for  installation  or  repairs,  disconnect  it  from  the 
electricity mains.

- The Allegro 576 is an independent control device for 

surface  assembly  with  wiring  through  tubes  for 
correct installation.

- Electrical connections other than those indicated in 

this manual and on the connection label on the side 
of  the  device  are  not  permitted.  The  connections 
referred to in this manual are those of the regulator; 
to  connect  the  rest  of  the  components,  please 
consult the corresponding instructions for each unit 
(collectors,  tanks,  valves,  etc.).  For  correct 
operation of the installation, check that the technical 
needs of the elements are compatible.

- This regulator is not a security device nor can it be 

used as one; it is the responsibility of the installer to 
provide  the protection most suited to each type of 
installation (

officially authorised

).

- The assembly, electrical connection, commissioning 

and maintenance procedures must be carried out by 
qualified personnel.

- Should you encounter any defects that could cause 

damage or malfunctions, do not connect the device.

- Should you have any doubts regarding the operation 

or correct installation of the device, do not connect it 
to  the  electricity  mains  and  consult  a  professional 
technician.

- Sonder Regulación S.A. reserves the right to modify 

the product, technical data and assembly and use 
instructions without prior notification.

WARRANTY CONDITIONS

This device has  Three-year warranty. The warranty 

is limited to the replacement of faulty parts, which will 
be restored to the same condition in which they were 
received. No packaging, batteries, instructions or any 
other  accessories  included  with  the  product  will  be 
replaced.

We  cannot  accept  any  responsibility  for  devices 

damaged as a result of poor handling, omission of the 
warnings  provided  in  this  manual  or  technical 
ignorance  with  regard  to  the  requirements  of  the 
installation.

For repairs during the warranty period, customers 

are  required  to  provide  proof  of  purchase  and  an 
accurate  description  detailing  the  defect  or  the 
anomalous behaviour of the product according to the 
user.

In the event of repairs outside the warranty, the user 

will  be  informed  of  their  viability  and  cost. 
Assessments carried out by our technical department 
may incur an additional cost for the user.

The following cases are excluded from the warranty:

Devices whose serial number has been worn away, 

erased or modified.

Devices  which  were  not  connected  or  used  in 

accordance  with  the  instructions  enclosed  with  the 
device.

Devices  that  have  been  modified  without  prior 

agreement with the manufacturer.

Devices  damaged  due  to  knocks,  spills  or  gas 

emissions.

Devices  with  normal  wear  and  tear  or  which  are 

damaged from inappropriate use.

Shipment and reception costs.

Requests  for  compensation  for  loss  of  earnings, 

usage compensation and indirect damage, unless the 
company is deemed legally responsible.

4

WARNINGS

Moderato-SR

33

Probes 
- Radiation
- Temperature

New product

Versions to order
with probe
PTC2000

Remote adjustment probe 

with range from 6 to 30 ºC

Summary of Contents for Allegro 576 BOX

Page 1: ... Manual Energy control Avenida la Llana Nº 93 P I La Llana 08191 RUBÍ Barcelona Spain Tel 34 93 588 42 11 Fax 34 93 588 49 94 www sonder es info sonder regulacion com SONDER REGULACIÓN S A Allegro 576 RAIL code 20 043 Allegro 576 BOX code 20 054 ...

Page 2: ...5815VØ MAY 09 2 35 NOTES ...

Page 3: ...scription Technical specifications Dimensions Connections Operation Getting started Probe and relay test Screen view Configuration Factory settings and resetting Resource control Menu Statistics Functions Systems Settings 33 4 5 6 6 6 6 7 8 8 9 10 11 12 13 16 16 18 22 26 ...

Page 4: ...modify the product technical data and assembly and use instructions without prior notification WARRANTY CONDITIONS This device has Three year warranty The warranty is limited to the replacement of faulty parts which will be restored to the same condition in which they were received No packaging batteries instructions or any other accessories included with the product will be replaced We cannot acc...

Page 5: ...3 channels 3 alarms Telephone control landline mobile 1 channel 1 alarm Water meter with pulse output L 50mm L 100mm L 200mm Conductive paste for sheaths 5 PRESENTATION Stainless steel sheaths GSM Consult us about models for remote management and data storage with SD card Visit our WEBSITE New products All our products Technical documentation Catalogues www sonder es Consult our wide range of prod...

Page 6: ... has reached 45 the swimming pool is heated to dissipate the excess heat instead of accumulating it in the collectors thus preventing the installation from overheating Example with system 6 2 Accumulator priority ºC AC 1 AC 2 AC 3 65 40 5 H W U H Swimming pool In summer Tank alarm ºC AL 1 AL 2 AL 3 70 45 35 Since the underfloor heating does not need to be activated during the summer its priority c...

Page 7: ...each type of system If they are of use to you the device is ready to control and regulate your installation If due to the needs of your installation you require other settings read this section carefully In the menu you can adjust the parameters that define how the installation will operate default values and setting ranges SETTING RANGE ADJUSTED Adjustment mode Activation differential Deactivatio...

Page 8: ...lthough only 1 symbol is shown on the screen All the settings are preset to factory default values If these values do not suit the needs of your installation consult page 26 to configure them 8 OPERATION ESC OK 576 Sonder Accumulator cooling This parameter allows you to reduce the temperature of the accumulator by recirculating the collector when it detects that the collector temperature is lower ...

Page 9: ...key the system returns to normal operation and the relays return to the status required by the system at that time With the password OFF The system does not exit the test menu until the ESC key is pressed forced manual mode Then move on to the relays forced manual where you can manually activate deactivate each relay Press OK to activate deactivate relay R1 Press to move on to the next relay Press...

Page 10: ...LIGHT TIMER LIGHT parameter OFF 10 ESC OK 576 Sonder This screen informs you that The probe assigned to the radiator has a reading error S S OPERATION SETTINGS 27 Tank temperature alarm This parameter defines a temperature alarm for each accumulator depending on the system a unit heater or cooling system is activated another accumulator is charged or circulation is stopped In the PARÁMETROS menu p...

Page 11: ...to move to PARÁMETROS and then press OK In the menu you can adjust the settings that will define the operation of the installation Winter or summer mode Activation differential Deactivation differential Temperature alarm in tanks 1 to 6 Temperature differential general for all settings Minimum setting limit Maximum setting limit Minimum ambient limit Maximum ambient limit Separate calibration for ...

Page 12: ...limit Maximum setting limit Active system 1 1 1 tank 1 pump If the password is activated it is impossible to reset the values and restore the factory settings To do so it is necessary first to deactivate the password value 0 in the settings menu If an unauthorised user tries to reset the values he would press the ESC key for 10 seconds and only be able to enter the probe and relay test When you ex...

Page 13: ...3 3 1 3 2 3 3 5 1 5 2 5 3 6 1 6 2 6 3 4 1 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 13 OPERATION Hot water S4 S5 R3 S3 R5 R2 S1 S7 R6 A B C D EXCHANGER PURIFIER F R1 R4 S6 E S1 S2 S3 S4 S5 S6 S7 R1 ...

Page 14: ... S S S S S OK S S S S S S S S S S S S S S S S ESC S S S S S S S S S S OPERATION collector array 2 pumps 2 tanks collector array tank swimming pool 2 pumps collector array tank heating 2 pumps collector array 2 tanks pump 3 way valve collector array tank swimming pool pump 3 way valve collector array tank heating return pump 3 way valve 2 collector arrays east and west 2 tanks 2 pumps 3 way valve 2...

Page 15: ...n Use the keys to move on to the next system To confirm the chosen system press OK and press the ESC key to return the previous menu Once the system has been configured the unit saves the changes and returns to normal operation SYSTEMS The representation of the units on these diagrams is symbolic One solar panel means there is one array of solar collectors but when there are 2 it means that there ...

Page 16: ...e solar system you need for your installation and then the functions since you may not be able to configure the rest of the functions according to relays the systems leaves frees MENU Thermostat 1 2 3 independent Thermostat 1 2 ambient Anti frost Double pump alternation Cooling by unit heater Calorimeter Tubular sensor Return increase OR AND Regulates the temperature of a probe heating underfloor ...

Page 17: ...s ESC to return to the FUNCIONES menu This function conditions the status of a relay based on the status of all the selected relays For example if you choose R1 as the slave relay and R2 R4 and R6 as the main relays R1 will be activated when R2 AND R4 AND R6 are activated When any one of the main relays is off the slave relay switches off AND ESC OK 576 FUNCTIONS 20 Press OK to enter the function ...

Page 18: ...to enter the function settings where you can activate deactivate the function and set the total time that each pump will operate before changing 4 to 120 hours Press to change the flashing value and press OK to confirm the selection Press ESC to return to the FUNCIONES menu S S This function allows you to double a pump in your installation so that the two pumps work in alternation Double pump alte...

Reviews: