Independent thermostat 1

Ÿ

Independent thermostat 2

Ÿ

Independent thermostat 3

Ÿ

Ambient thermostat 1

Ÿ

Ambient thermostat 2

Ÿ

Anti-frost protection

Ÿ

Double pump alternation function

FUNCTIONS

The functions use the probes shared by the systems and the relays left free by 
the systems and other functions.

If  you  try  to  configure  more  functions  than  supported  by  the  unit,  the  VOID 
message will appear on the screen and it will exit the function.

Ÿ

Activation of cooling by unit heater

Ÿ

Calorimeter

Ÿ

Specific function for tubular sensors

Ÿ

Increase of the return temperature from the heating 
circuit

Ÿ

OR function

Ÿ

AND function

18

Independent thermostat

ESC

OK

576

Sonder

- Press 

OK

 to enter the function settings where you can activate/deactivate the 

function, set the temperature to be regulated (10 to 90 ºC), the reading probe 
and the relay activated. Press              to change the flashing value and press 

OK 

to confirm the selection.

- Press 

ESC

 to return to the

 FUNCIONES

 menu

.

S S

This function allows you to install one or two remote adjustment probes (

MODERATOR SR

) in your installation. This allows you 

to regulate the temperature of the room without having to change the temperature setting using the Allegro 576. 

Ambient thermostat

Thermostat 2

Thermostat 1

Thermostat 3

- Press 

OK

 to enter the function settings to activate/deactivate the function, set the 

setting probe (to select the temperature at which the room must be kept), the 
regulation probe (it will take the reading of the room temperature) and the relay 
to be activated. Press               to change the flashing value and press 

OK

 to 

confirm the selection.

- Press 

ESC

 to return to the 

FUNCIONES

 menu.

S

S

This function allows you to regulate the temperature of a probe (underfloor heating, central heating, thermostat, etc.) regardless 
of the chosen solar system.

It has three independent thermostat functions, each one of which has a 
different icon so that you can easily tell which one the data on the screen 
relates to in normal mode.

Although the icons are different, they operate in the same way.

To access the functions menu, press             for 5 seconds (with the screen lit), use the arrows to select the 

functions

 

menu and then press 

OK

. In the menu you will find:

Thermostat 2

Thermostat 1

ESC

OK

576

Sonder

2

Once you have configured and installed the remote probe you have to calibrate 

the reading on the button of the remote terminal with the value of the Allegro 576 
reading. To do this:

- Set the button of the remote probe to 20 ºC.
- Enter 

menú, parámetros

 and 

calibrado de sondas.

- Change the value of the setting probe to 20 ºC 

Example setting probe 

S4

: on screen the reading from this probe is 19.5 ºC, go 

to probe calibration and change the value of S4 from 0.0 to 0.5.

S S

ESC

OK

576

Sonder

MENU

19

- Press 

OK

 to enter the function settings, where you can activate/deactivate the 

function and set the total time that each pump will operate before changing (4 to 
120 hours). Press             to change the flashing value and press 

OK

 to confirm 

the selection.

- Press 

ESC 

to return to the 

FUNCIONES

 menu.

S S

This function allows you to double a pump in your installation so that the two pumps work in alternation.

Double pump alternation

ESC

OK

576

Sonder

FUNCTIONS

- Press 

OK

 to enter the function settings, where you can activate/deactivate the 

function,  set  the  temperature  (40  to  140  ºC),  the  reading  probe  and  the 
recirculation or unit heater activation relay. Press              to change the flashing 
value and press 

OK

 to confirm the selection.

- Press 

ESC

 to return to the 

FUNCIONES

 menu.

S S

This function allows you to reduce the temperature of a device by recirculating the circuit or a cooling device. The configured 
relay is activated when it detects that the temperature of the device is higher than the temperature of the circuit

Cooling by unit heater

ESC

OK

576

- Press

 OK

 to enter the function settings, where you can activate/deactivate the 

function, adjust the configuration of the pulse input (1 to 200 litres per pulse), the 
composition of the heat-transfer liquid (0 to 100% glycol) the input probe and the 
meter probe (at the input and output of the accumulator to calculate the amount 
of heat transferred). Press the keys             to change the flashing value and 
press 

OK

 to confirm the selection.

- Press 

ESC

 to return to the 

FUNCIONES 

menu.

S S

This function measures the amount of energy supplied to your installation by the solar collector by reading two probes (one 
at the input and the other at the output of the part of the installation you want to control) and the pulse input (it measures 
the flow rate of the installation).

Calorimeter

ESC

OK

576

Sonder

- Press 

OK

 to enter the function settings, where you can activate/deactivate the 

function, set the temperature at which the pump is to be activated (-20 to 20 ºC) 
and the relay that will circulate the water from the accumulator through the circuit 
of the installation to the solar collector. Press                         to change the flashing 
value and press 

OK

 to confirm the selection.

- Press

 ESC 

to return to the 

FUNCIONES 

menu.

S S

The anti-frost function has been designed for installations that use water as a heat-transfer liquid. Since it does not contain any 
anti-freeze, the heat of the installation is used to prevent the circuit from freezing.

Anti-frost

ESC

OK

576

Sonder

- Press 

OK

 to enter the function settings, where you can activate/deactivate the 

function. Press             to change the flashing value and press 

OK

 to confirm the 

selection.

- Press 

ESC

 to return to the 

FUNCIONES

 menu.

S S

This updates the reading of the probes installed outside the collectors by recirculation for 30 seconds when it detects that the 
temperature has increased 2K with regard to the last memorised reading.

Tubular sensors

ESC

OK

576

Sonder

MENU

Summary of Contents for Allegro 576 BOX

Page 1: ... Manual Energy control Avenida la Llana Nº 93 P I La Llana 08191 RUBÍ Barcelona Spain Tel 34 93 588 42 11 Fax 34 93 588 49 94 www sonder es info sonder regulacion com SONDER REGULACIÓN S A Allegro 576 RAIL code 20 043 Allegro 576 BOX code 20 054 ...

Page 2: ...5815VØ MAY 09 2 35 NOTES ...

Page 3: ...scription Technical specifications Dimensions Connections Operation Getting started Probe and relay test Screen view Configuration Factory settings and resetting Resource control Menu Statistics Functions Systems Settings 33 4 5 6 6 6 6 7 8 8 9 10 11 12 13 16 16 18 22 26 ...

Page 4: ...modify the product technical data and assembly and use instructions without prior notification WARRANTY CONDITIONS This device has Three year warranty The warranty is limited to the replacement of faulty parts which will be restored to the same condition in which they were received No packaging batteries instructions or any other accessories included with the product will be replaced We cannot acc...

Page 5: ...3 channels 3 alarms Telephone control landline mobile 1 channel 1 alarm Water meter with pulse output L 50mm L 100mm L 200mm Conductive paste for sheaths 5 PRESENTATION Stainless steel sheaths GSM Consult us about models for remote management and data storage with SD card Visit our WEBSITE New products All our products Technical documentation Catalogues www sonder es Consult our wide range of prod...

Page 6: ... has reached 45 the swimming pool is heated to dissipate the excess heat instead of accumulating it in the collectors thus preventing the installation from overheating Example with system 6 2 Accumulator priority ºC AC 1 AC 2 AC 3 65 40 5 H W U H Swimming pool In summer Tank alarm ºC AL 1 AL 2 AL 3 70 45 35 Since the underfloor heating does not need to be activated during the summer its priority c...

Page 7: ...each type of system If they are of use to you the device is ready to control and regulate your installation If due to the needs of your installation you require other settings read this section carefully In the menu you can adjust the parameters that define how the installation will operate default values and setting ranges SETTING RANGE ADJUSTED Adjustment mode Activation differential Deactivatio...

Page 8: ...lthough only 1 symbol is shown on the screen All the settings are preset to factory default values If these values do not suit the needs of your installation consult page 26 to configure them 8 OPERATION ESC OK 576 Sonder Accumulator cooling This parameter allows you to reduce the temperature of the accumulator by recirculating the collector when it detects that the collector temperature is lower ...

Page 9: ...key the system returns to normal operation and the relays return to the status required by the system at that time With the password OFF The system does not exit the test menu until the ESC key is pressed forced manual mode Then move on to the relays forced manual where you can manually activate deactivate each relay Press OK to activate deactivate relay R1 Press to move on to the next relay Press...

Page 10: ...LIGHT TIMER LIGHT parameter OFF 10 ESC OK 576 Sonder This screen informs you that The probe assigned to the radiator has a reading error S S OPERATION SETTINGS 27 Tank temperature alarm This parameter defines a temperature alarm for each accumulator depending on the system a unit heater or cooling system is activated another accumulator is charged or circulation is stopped In the PARÁMETROS menu p...

Page 11: ...to move to PARÁMETROS and then press OK In the menu you can adjust the settings that will define the operation of the installation Winter or summer mode Activation differential Deactivation differential Temperature alarm in tanks 1 to 6 Temperature differential general for all settings Minimum setting limit Maximum setting limit Minimum ambient limit Maximum ambient limit Separate calibration for ...

Page 12: ...limit Maximum setting limit Active system 1 1 1 tank 1 pump If the password is activated it is impossible to reset the values and restore the factory settings To do so it is necessary first to deactivate the password value 0 in the settings menu If an unauthorised user tries to reset the values he would press the ESC key for 10 seconds and only be able to enter the probe and relay test When you ex...

Page 13: ...3 3 1 3 2 3 3 5 1 5 2 5 3 6 1 6 2 6 3 4 1 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 13 OPERATION Hot water S4 S5 R3 S3 R5 R2 S1 S7 R6 A B C D EXCHANGER PURIFIER F R1 R4 S6 E S1 S2 S3 S4 S5 S6 S7 R1 ...

Page 14: ... S S S S S OK S S S S S S S S S S S S S S S S ESC S S S S S S S S S S OPERATION collector array 2 pumps 2 tanks collector array tank swimming pool 2 pumps collector array tank heating 2 pumps collector array 2 tanks pump 3 way valve collector array tank swimming pool pump 3 way valve collector array tank heating return pump 3 way valve 2 collector arrays east and west 2 tanks 2 pumps 3 way valve 2...

Page 15: ...n Use the keys to move on to the next system To confirm the chosen system press OK and press the ESC key to return the previous menu Once the system has been configured the unit saves the changes and returns to normal operation SYSTEMS The representation of the units on these diagrams is symbolic One solar panel means there is one array of solar collectors but when there are 2 it means that there ...

Page 16: ...e solar system you need for your installation and then the functions since you may not be able to configure the rest of the functions according to relays the systems leaves frees MENU Thermostat 1 2 3 independent Thermostat 1 2 ambient Anti frost Double pump alternation Cooling by unit heater Calorimeter Tubular sensor Return increase OR AND Regulates the temperature of a probe heating underfloor ...

Page 17: ...s ESC to return to the FUNCIONES menu This function conditions the status of a relay based on the status of all the selected relays For example if you choose R1 as the slave relay and R2 R4 and R6 as the main relays R1 will be activated when R2 AND R4 AND R6 are activated When any one of the main relays is off the slave relay switches off AND ESC OK 576 FUNCTIONS 20 Press OK to enter the function ...

Page 18: ...to enter the function settings where you can activate deactivate the function and set the total time that each pump will operate before changing 4 to 120 hours Press to change the flashing value and press OK to confirm the selection Press ESC to return to the FUNCIONES menu S S This function allows you to double a pump in your installation so that the two pumps work in alternation Double pump alte...

Reviews: