[1]. Press button to position the garage door in the low position.
3
4
2
1
Prog
STOP
[2]. Attach the magnet to the edge of the runner, positioning it in line with the
transmitter.
This operation is important. Ensure the dimensions are observed.
10 mm maxi.
Lower
magnet
4.3 Programming the XSE transmitter
[1]. Press the
Prog
button on the receiver until the indicator light comes on
permanently.
[2]. Using the tip of a pen, press the transmitter PROG push-button for 4
seconds.
Indicator light 2 on the receiver goes out and the receiver Prog
LQGLFDWRUOLJKWZLOOÀDVKDQGWKHQJRRXWWKLVPD\WDNHDIHZVHFRQGVZKLOH
the transmitter and receiver communicate with each other).
The transmitter is memorised in the receiver.
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
4 s
4.4 Recognition of the lower magnet
It is essential that the following procedure is observed to ensure
completely safe operation of the door.
The door must be in the intermediate position before the lower
magnet recognition procedure can be started.
Do not press the safety edge during the lower magnet recognition
procedure.
Run a complete cycle (opening then closing) using buttons and .
3
4
2
1
Prog
STOP
3
4
2
1
Prog
STOP
WARNING
At the end of installation, it must be checked that the limitation of forces
complies with appendix A of the standard EN 12 453.
5 - CHECKING OPERATION OF THE
RECEIVER
5.1 Operation in sequential mode
STOP
STOP
STOP
5.2 Integrated lighting
The lamp comes on each time a command is sent to the receiver.
It goes out 2 minutes after the door stops.
5.3 Orange light
7KHRUDQJHOLJKWÀDVKHVHYHU\WLPHWKHUHFHLYHULVFRQWUROOHGZLWKRUZLWKRXWD
VHFRQGZDUQLQJGHSHQGLQJRQWKHFRQ¿JXUHGSDUDPHWHUVHWWLQJ
,WVWRSVÀDVKLQJZKHQWKHGRRUVWRSV
5.4 Cells
If the cells are blocked when the door is closed, it stops, then re-opens fully.
If the cells are blocked when the door is opened, the door continues its
movement.
5.5 Safety edge
If the safety edge is activated when the door is closing, it stops then re-opens
partially.
If the safety edge is activated while the door is opening, it continues its
movement.
5.6 Alarm (optional)
The alarm is triggered for 2 minutes if the door is fully closed and raised
manually. No movement of the door is possible when the alarm is sounding.
When the alarm sounds, press a button on a remote control memorised in the
receiver to stop it.