C 1
C 2
C 3
C 4
C 5
C 6
C 7
C 8
C 9
C A
C B
C C
d O to d 9
d d
Control stand-by
Gate opening
Closing stand-by
Gate closing
DMAOP safety device blanked
Cell opening safety device blanked
Cell closing safety device blanked
Forced movement via keyboard
Emergency stop triggered
Safety device autotest in progress
Permanent control validated
Time delay stand-by shutdown
before reversion
Display of last 10 defaults
Default deletion
Opening safety device default (always contact)
Closing 1 safety device default (always contact)
Closing 2 safety device default (always contact)
Opening safety device default (default autotest)
Closing 1 safety device default (default autotest)
Closing 2 safety device default (default autotest)
Overload 24V, intensity overrun
Intrusion default
Motor thermal safety device
Motor slipping default
Limit switch default
See default code above
By pressing on VALID for 5 s
E 1
E 2
E 3
E 4
E 5
E 6
E 7
E 8
E 9
E A
E B
X X
- -
t 0
t 1
t 2
t 3
t 4
t 5
t 6*
t 7
t 8
t 9
t A
Closing time (free passage)
Zone lighted time after end of cycle
Waiting time after passage in front of cell
Motor 1 and 2 ramp rate time
Motor 1 operating time (high speed)
Motor 2 operating time (high speed)
Motor 1 and 2 operating time (low speed)
Time lag when opening
Time lag when closing
Opening time for pedestrian
Waiting time before motor reversion
(1 s increment)
(1 min increment)
(1 s increment)
00 to 99 s (
05
)
00 to 10 min (
00
)
00 to 99 s (
00
)
00 to 02 s (
01
)
00 to 80 s (
10
)
00 to 80 s (
10
)
00 to 30 s (
00
)
00 to 99 s (
02
)
00 to 99 s (
05
)
00 to 99 s (
05
)
00 to 30 s (
02
)
23
Time delay setting
The values indicated in
grey
correspond to factory settings.
Parameter displayed
Delay setting
Function
Value displayed
Operational control
and troubleshooting
Display
Meaning Meaning
Display
Complete list of parameters (cont.)
GB
* Some types of motor (tubular, brake motor …) cannot operate at low speed (serious vibrations). In that case,
set t6 to 0.