![background image](http://html1.mh-extra.com/html/somfy/fts-hi-pro-series/fts-hi-pro-series_manual_1317554008.webp)
www.somfy.com
page7
FTS system operating principle
Operation of the FTS
Control
Control unit
Actuators
Actuator power supply
Press (1/2 sec.) on
the awning in
button.
Outputs timed until
the end limit is
reached or the "stop"
command is made
using the reverse
control.
The fabric tube rolls the fabric, the
strap tube brakes the straps slightly
to prevent excessive sagging (dynamic
tension).
Dynamic
braking
Roller
Power supply:
for the 2 actuator brakes.
•
for the fabric actuator in the
•
direction that corresponds to
the rolling of the fabric.
for the strap actuator at
•
reduced tension (dynamic
tension).
Press both
buttons,
or on the awning
out button,
or stop at end
limit of the
system.
Output timed by the
final tension setting.
The fabric tube is locked, the strap tube
rolls the straps to tension them for the
duration of the final tension delay.
Power supply:
for the strap actuator brake.
•
for the strap actuator in the
•
direction that corresponds to
the rolling of the straps.
Summary of Contents for FTS Hi-Pro Series