![background image](http://html1.mh-extra.com/html/somfy/fts-hi-pro-series/fts-hi-pro-series_manual_1317554020.webp)
www.somfy.com
page19
FTS system installation guide
ON
OFF
OFF
ON
;(+
;,
;
;,,
;,,,
;,9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
The earth wires (yellow/green) from the 2 actuators must be connected to the power supply earth on 1 electric split fitting separate from
•
the circuit.
One-touch control via double push buttons (stop by pressing both push buttons).
•
The control box is equipped with a selection
•
switch(X) for the power supply frequency: make
sure this switch is disengaged to correspond to
European voltage:
Check that the dipswitches
•
(
XII
) are in the ON
position to obtain symmetrical dynamic voltage
when the fabric is unwound and wound up.
(except specific cases approved beforehand by
Somfy's technical service.)
Make sure that the potentiometers
•
(
XIII
) and
(
XIV
) are in position "0" so that the dynamic and
final tensions are at minimum.
OFF
OFF
)86(
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
Power supply
1:
Live
2:
Neutral
3:
Shared by actuators (blue wires from straps and fabric
actuators)
Straps actuator
4:
Straps winding (black or brown wire from actuator)
5:
Straps tension (brown or black wire from actuator)
6:
Straps electro-brake (grey wire from actuator)
Fabric actuator
7:
Fabric winding (black or brown wire from actuator)
8:
Fabric tension (brown or black wire from actuator)
9:
Fabric electro-brake (grey wire from actuator)
C safety
10:
Control shared
11:
Fabric unwinding control
12:
Fabric winding control
13:
Aperture safety (if not used, leave electric bridge
between terminals 10 and 13)
50 Hz power supply.
Switch
60 Hz power supply.
Switch
Factory configuration for Europe
Do not feed the actuators' power supply
cables and the control and safety cables
through the same sheath.
ON
ON
OFF
OFF
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
11. Control box terminal blocks
12. Checks before wiring