- Replacing the EXAVIA 500 / WISPA 800 / SGS 201SGS 400 / SGS 501 electronic unit - SOMFY
GENERAL INTRODUCTION
1
These instructions describe the procedure for replacing the control unit for Exavia, Wispa and SGS motors.
1.1 Technical data
Power supply
230 V-50Hz/24 V (with solar power)
Motor type
24 V
Motor output
120 W
Max. power consumed
(with area lighting)
600 W
Standby consumption
3 W (without accessories)
Maximum frequency of move-
ments per day
20 cycles per day
10 cycles per day using solar power
Opening time
20 s minimum to 90°
Automatic obstacle detec-
tion
Compliant with standard EN 12 453
Operating temperature
-20°C to +60°C
Thermal protection
Yes
Index protection rating
IP 44
2.3 Installing the sealing strip
2.1 Switching the installation off
Cut off the mains power supply.
2.2 Disconnecting the power supply, motors and additional devices
Open the control unit.
Disconnect all the cables coming into the control unit terminal.
Remove the unit being replaced.
REPLACING THE CONTROL UNIT
2
Built-in radio receiver
Yes
Remote controls:
- Radio frequency
- Range in field of use
- Storage quantity
433.42 MHz
~ 30 m
16
Possible connections:
- Output for flashing light
- Lighting output
- Accessories power supply
output
- Back-up battery input
- Photo-electric cell input
- Dry contact type control input
Flashing, 24 V, 10 W max.
500 W max. 230 V (halogen or
incandescent lights only)
24 Vdc/15 W max.
Yes
Yes
Yes (does not operate if battery
power supply
or solar power supply)
Mark the cables (motor 1, motor 2, accessories, power supply) so it is easier to connect them to the new electronics. N.B.,
we regularly improve our products. The terminals on these new electronics may differ from the electronic terminals being
replaced.
Fit sealing strip (3) inside the top of the control unit.