- Replacing the EXAVIA 500 / WISPA 800 / SGS 201SGS 400 / SGS 501 electronic unit - SOMFY
6.1 General wiring diagram for the accessories
6.2 Cells
TX
1 2
1 2 3 5
RX
BUSBUS
33
44
Installation
Aer wiring the photoelectric cells:
•
switch the motor on again,
•
start a gate opening or closing
procedure.
The photoelectric cells are recognised by
the control electronics once this movement
is complete.
Operation with
photoelectric cells
If the cells are blocked when closing the
gate, the gate will stop and reopen.
230 V power
supply
Coaxial cable
In the event of photoelectric cell disconnection
Aer disconnecting the photoelectric cells, switch the motor on again then perform the procedure “Deactivating automatic closing -
returning to standard operation” on page 14.
TX
1 2
RX
BUSBUS
33
44
1 2
1 2
or
WIRING THE ACCESSORIES
6
For your safety, these operations must be carried out with the power supply switched off.
You are advised to perform auto-programming of the gate leaves’ travel before connecting the accessories (photoelectric cells, flashing
light, etc.)
It is not possible to connect a second set of photoelectric cells on this electronic unit.