EXTRACTOR DRIVE MOTOR REMOVAL
1.
After turning the circuit breaker off, remove cover on drive motor junction box and disconnect motor
leads.
2. Remove conduit from motor junction box.
3. The drive motor (1) can be removed from the head assembly by removing four screws (2).
EXTRACTOR GEAR REDUCER REMOVAL
1. R
emove bolt (3) and four machine screws (4).
EXTRACTOR SCREEN AND SCREW REMOVAL
1.
After removing four machine screws (5), from head assembly (6) lift head with screen (7) and screw
assembly (8) attached, from the Hydra-Extractor
shell (9).
2. Remove the screw assembly from the screen assembly by pulling the screw assembly through the
bottom opening of the screen, while turning bottom of screw counterclockwise with a pipe wrench.
3. After removing the screw assembly, remove two button head machine screws (10), from the screen
and slip the screen from the head assembly.
EXTRACTOR BOTTOM PIN REMOVAL
1.
Remove six machine screws (11.)
2. The bottom pin plate (12) with bottom pin (13) attached can now be removed.
3. Remove screw (14). The bottom pin can now be separated from the bottom pin plate.