112302-901-08/04
OSM 4000
21 / 26
4.2.6
Interface J3 Cable
Interface J3 (RS-232)
•
usable with an IMU / INS to receive NMEA frames or similar data
•
connector type: D-Sub 9-way, female, 4-40 UNC thread (see below table for pin assignment).
•
The IMU / INS system must be installed on top of the Stabilization Mount! An installation at a
different location will lead to a performance reduction.
•
It is not possible to use Interface J2 AUX and J3 AUX simultaneously. If devices are connected to both
interfaces, J3 has priority.
Connector D-Sub 9-way, fe-
male, 4-40 UNC thread
Interface J3 (RS-232)
Pin
Function
1
n.c.
1
2
TxD
3
RxD
4
n.c.
1
5
signal-GND
6 … 9
n.c.
1
housing
ground
4.3
SOMAG Mount Control App Installation
Information regarding the installation of the SOMAG Mount Control App can be found in the following docu-
ment: ‘110080
-901-
08/XX SOMAG Mount Control App Manual’.
1