139
19.
Installing and operating with the remote control -
“programmable thermostat” (optional)
The pellets stove is mass produced with a remote control (
display
). Alternatively, the
unit can be operated using a generic remote-control unit (programmable thermostat)
or other type of remote control, as long as it is a no-voltage contact.
To remotely connect the pellet burning unit to a programmable thermostat or a
thermostat, you must use the provided interface (Figure 144-b), which is a board
located on the right side of the unit (Figure 143).
Figure 146 – Interface board location
This board has two inputs: “remote” and “thermostat”. When connecting the
programmable thermostat to the “remote” input, the user gives the start order (closed
contact NC) and the stop order (open contact NO).
If you connect it to the “thermostat” input, the unit's power will only vary between
minimum operating power (open contact NO) and maximum operating power (closed
contact NC).
Note:
the remote control is usually supplied with an instruction manual.
Models K300 e K400