136
a) b) c)
Figure 139 – a) Ash basket; b) Grid; c) Burner basket
It is also necessary to clean the interior of the salamander by opening the trapdoor, as
shown in Figure 137. Finally, assemble the parts in the reverse order from which they
were removed and close the appliance door.
a)
b)
Figure 140 – Cleaning the Pellet Fire Unit's interior
WARNING! The maintenance task frequency depends on the quality of the
pellets.
Note:
See the warning label and read the maintenance instructions in chapter 19.
18.3.
Additional cleaning
Additional cleaning should be performed for every 1300-1700 lbs (600-800 kg) of
pellets consumed.
Remove the side covers to access the side lids of the combustion chamber. To clean the
interior of the unit, remove the screws (Figure 141-a and Figure 142-a), remove the lid
and vacuum the ashes. Using a 20-25mm wide 80cm long steel brush thoroughly clean
the fume ducts (Figure 143-a and Figure 144-a).