The free-standing pellet fire requires a clear space around the unit for proper
combustion, so possible air tightness of the location or any existing air extraction
sources in the room may prevent the unit proper operation;
•
The existence of vents is a requisite for proper combustion;
•
Do not leave the packing materials near children;
•
During normal operation, Free Standing Fire unit's door must not be opened;
•
Some parts of the unit may overheat during normal operation, so avoid direct
contact with parts such as the door handle and glass;
•
Check the existence of any obstructions on the fume duct before turning on the
unit after a long period of inactivity;
•
This free-standing pellet fire unit is intended for residential use in protected areas.
Safety systems may turn off the unit. If this occurs, contact the technical assistance.
In any circumstances should you attempt to interfere with the safety systems;
•
The free-standing pellet fire is a biomass heating unit equipped with an electric
fume extractor. The occurrence of any power failure during its use may prevent fume
extraction and the room will be filled with smoke. For this reason, you should have a
natural fume extraction system, like a chimney, available;
•
Solzaima offers you an optional safety system which allows the Free-Standing Fire
unit to be connected to a UPS so that during any power failure the fume extractor will
still operate until complete extraction of all the fumes;
•
If you intend to use the Free-Standing Fire unit while you are away from home or
unattended, you should use the safety system specified above for total safety during
any power failure;
•
During operation, NEVER turn off the free-standing fire unit by disconnecting the
electric plug. The fume extractor on the free-standing pellet fire unit is electric so
disconnecting the power plug will prevent the extraction of combustion fumes;
•
Your unit must be disconnected from the mains for servicing. Before doing this, the
unit must be totally cooled down (if operating before);
•
Never touch the interior of the unit without disconnecting it from the power mains;
•
On back boiler models, the maximum temperature of the water that can be set by
the user (water set-point temperature) is 85°C. In the event of a temperature of 90ºC
being reached, the free-standing pellet fire unit automatically disconnects and the
respective alarm is activated.
Summary of Contents for Hidro 12
Page 18: ...12 Figure 11 specifies the basic requirements for installing the chimney to the unit a b ...
Page 102: ...96 ...
Page 103: ...97 ...
Page 104: ...98 ...
Page 133: ...127 25 2 Flow chart Hidro 12 Flow chart 1 Lighting ...
Page 134: ...128 ...
Page 135: ...129 Flow chart 2 Disabling Note The circulator pump off below 40 C water temperature ...
Page 136: ...130 25 3 Flow chart Hidro 17 and Hidro 23 Flow chart 1 Lighting ...
Page 137: ...131 ...
Page 138: ...132 Flow chart 2 Disabling Note The circulator pump off below 40 C water temperature ...