PRODUCTS DETAILS 

 

This document is valid for all products below: 

 

FR

AM

ED

 

DAS MODUL MONO VI / X 

DMMVI / DMMX 

Single glass 

White / Black 

DAS MODUL MONO 

DMM 

Single glass 

White/ Black 

DAS MODUL POLY  

DMP 

Single glass 

White / Black 

DAS MODUL MONO PURE GLASS 

VI / X 

DMMVIPG / 

DMMXPG 

Glass glass 

Transparent / black 

DAS MODUL MONO VI GEMINI  

DMMVI_GEMINI 

Single glass 

Bifacial 

Transparent 

FR

AM

EL

ESS

 

POWERSLATE MONO VI 

PSMVI 

Single glass 

Black/White/Transparent 

POWERSLATE MONO VI PG 

PSMVIPG 

Glass glass 

Black/White/Transparent 

 

Label explanation: 

 

All Modules from SOLUXTEC have their own label on 

back.  

This  label summarizes  the module data sheet as 

follows: 

Place of production 

Commercial name 

STC (standard test condition) data: 

- Pmpp : Power in watt at maximum power point 

- Isc : Short circuit Intensity in ampere 

- Impp : Intensity in ampere at power point  

- Voc : Voltage in volt in open circuit 

- Vmpp : Voltage in volt at power point 

For more details about mechanical or electrical module 

behaviour, please refer to dedicated data sheet. 

 

Serial number codification: 

S T U V WW XX YYY ZZZZ, where: 

 

S =  

D for DAS MODUL 

P for POWERSLATE 

T = 

F for foil module 

G for Glass Glass module 

U = 

A for solar cell mono M6 

B for solar cell mono M10 

C for solar cell mono M3 

D for solar cell poly 157 mm² 

E for solar cell mono M6 Bifacial 

F for solar cell mono M10 Bifacial 

G for solar cell mono M3 bifacial 

V =  

1 for production in FAB 1 Bitburg 

2 for production in FAB 2 Trier 

W = 

month of production 

X = 

year of production 

Y =  

Production order number 

Z = 

Module number from above Production Order number. 

Summary of Contents for DMMVI370

Page 1: ...USER GUIDE SOLUXTEC SOLAR PRODUCTS...

Page 2: ...TION 3 2 BASIC SAFETY INSTRUCTIONS 3 3 REGULATION 4 4 TRANSPORTATION AND HANDLING 4 5 PRODUCT DETAILS 5 6 INSTALLATION 6 Modules Design 6 Precaution 8 Installation Option 10 7 ELECTRICAL INSTALLATION...

Page 3: ...of installation It is imperative to refer to the standards of each local authority in case specifics rules are imposed Installation of photovoltaic modules must be operated by qualified people with su...

Page 4: ...m number of pallets to be stacked Only original SOLUXTEC packaging is allowed for pallet stacking When unpacking modules please wear soft and clean gloves It is forbidden to use suction cup to carry t...

Page 5: ...e of production Commercial name STC standard test condition data Pmpp Power in watt at maximum power point Isc Short circuit Intensity in ampere Impp Intensity in ampere at power point Voc Voltage in...

Page 6: ...wing guidelines need to be respected on site MODULE DESIGN PRESENTATION Frame design for M6 solar cells modules DMMVI DMMVI_GEMINI DMMVIPG Frame design for M10 solar cells modules DMMX DMMXPG 1038 mm...

Page 7: ...ign for Poly and Mono M3 solar cells modules DMP DMM Frameless Design for M6 solar cells Module Glass Foil Glass Glass PSMVI total thickness of 5 5 mm PSMVIPG total thickness of 6 5 mm 1005 mm 1665 mm...

Page 8: ...could result in a significant energy loss SOLUXTEC s PV modules can be installed only with mounting structures Mounting structures need to comply with any applicable laws specific to the country of in...

Page 9: ...ame flange For module series equipped with a water drain corner clamp must not be applied directly on Please refer to the table on next page showing the different installation options from SOLUXTEC s...

Page 10: ...afety factor of 1 5 With Clamps DMP DMM DMMIV DMMX DMMIVPG DMMXPG PSMVI PSMVIPG Test 8100 2400 Design 5400 1600 Test 2400 2400 Design 1600 1600 Test 8100 2400 Design 5400 1600 Test 2400 2400 Design 16...

Page 11: ...With Mounting Holes DMP DMM DMMIV DMMX DMMIVPG DMMXPG DMMIV DMMX DMMIVPG DMMXPG GEMINI Test 8100 2400 Design 5400 1600 Test 8100 2400 Design 5400 1600 Test 2400 2400 Design 1600 1600 Y 410 X 200 X 50...

Page 12: ...solution supplier for the set PV module mounting system clamp system All accessories such as bolt screws and other metal parts are corrosion proof and exempt of any chemical reaction with the frame of...

Page 13: ...in a good shape The final wiring conception is determined in relation to the final project on site Modules deployed for a given project should present the same technical characteristics to prevent an...

Page 14: ...e need to consider the voltage open circuit and the minimal temperature on site You can calculate it with the following formula 1 25 Where N number of modules in serial Uoc Open circuit voltage of a m...

Page 15: ...a fire departure This point is extremely important All framed modules need to be connected together with a grounding solution to the main equipotential bonding of the project location On each module...

Page 16: ...company having realised the installation in order to control the efficiency of the complete generator Dust or pollution from the environment may gather on the surface of PV modules Hence it is recomme...

Page 17: ...17 SOLUXTEC USER GUIDE 2021_Version 1 a_ALL RIGHTS RESERVED SOLUXTEC GmbH Werner von Siemens Str 25 D 54634 Deutschland HRB Wittlich 41318 info soluxtec de...

Reviews: