background image

SOLUXTEC USER GUIDE 2021_Version 1/a_ALL RIGHTS RESERVED 

INTRODUCTION 

 

Thank you for electing SOLUXTEC GmbH PV modules. The following user guide covers 

important instructions to be read and understood before installation of SOLUXTEC products. 

This document does not have any relation to quality warranties and only acts as a user guide 

for electrical, mechanical and general handling safety of SOLUXTEC products. 

 

In  case PV  installation is not respecting below  mentioned points, the quality warranty of 

SOLXTEC products will become invalid. 

This document belongs to SOLUXTEC and all content is SOLUXTEC intellectual property. 

SOLUXTEC reserves the right to modify this document without prior notice. 

 

-  Please read this document carefully before installation 

 

-  Please make sure that this document is always available for installers and operators to 

handle SOLUXTEC products. 

 

-  Please give a copy of this document to the installation owner. 

 

-  If any questions are not well answered in this document, please contact SOLUXTEC 

support prior installation. 

 

 

SAFETY 

 

 

The installation of photovoltaic modules must respect the current standards from the 

place of installation. It is imperative to refer to the standards of each local authority 

in case specifics rules are imposed. 

 

 

Installation of photovoltaic modules must be operated  by qualified people  with 

sufficient knowledge of all regulations and compliance requirements specific to the 

country of installation. 

 

 

Solar modules create DC electricity and are even energized under a slight 

illumination level. Several modules connected together may occur an accumulation 

of voltage and intensity. Please respect all personal security to avoid a risk of 

electrocution. 

 

 

Please respect the data given from the elected module’s data sheet to respect all 

module’s limits and comply with other materials that will be need to operate the 

photovoltaic generator.  

 

 

 

-  Never open the junction box on the back of the photovoltaic module 

-  Make sure that connectors are clean and not dirty or wet before connection. 

-  Never disconnect the photovoltaic connector under load. Always turn off the DC breaker 

prior to any photovoltaics connector disconnection. 

-  Tools must be dedicated for solar installation and supporting DC current. 

-  The final photovoltaic generator must follow all needed standards and requirements in 

compliance with the installation country (PV, inverter, cable, grounding and other 

accessories from the PV generator). 

-  Never disassemble any part of the module. 

Summary of Contents for DMMVI370

Page 1: ...USER GUIDE SOLUXTEC SOLAR PRODUCTS...

Page 2: ...TION 3 2 BASIC SAFETY INSTRUCTIONS 3 3 REGULATION 4 4 TRANSPORTATION AND HANDLING 4 5 PRODUCT DETAILS 5 6 INSTALLATION 6 Modules Design 6 Precaution 8 Installation Option 10 7 ELECTRICAL INSTALLATION...

Page 3: ...of installation It is imperative to refer to the standards of each local authority in case specifics rules are imposed Installation of photovoltaic modules must be operated by qualified people with su...

Page 4: ...m number of pallets to be stacked Only original SOLUXTEC packaging is allowed for pallet stacking When unpacking modules please wear soft and clean gloves It is forbidden to use suction cup to carry t...

Page 5: ...e of production Commercial name STC standard test condition data Pmpp Power in watt at maximum power point Isc Short circuit Intensity in ampere Impp Intensity in ampere at power point Voc Voltage in...

Page 6: ...wing guidelines need to be respected on site MODULE DESIGN PRESENTATION Frame design for M6 solar cells modules DMMVI DMMVI_GEMINI DMMVIPG Frame design for M10 solar cells modules DMMX DMMXPG 1038 mm...

Page 7: ...ign for Poly and Mono M3 solar cells modules DMP DMM Frameless Design for M6 solar cells Module Glass Foil Glass Glass PSMVI total thickness of 5 5 mm PSMVIPG total thickness of 6 5 mm 1005 mm 1665 mm...

Page 8: ...could result in a significant energy loss SOLUXTEC s PV modules can be installed only with mounting structures Mounting structures need to comply with any applicable laws specific to the country of in...

Page 9: ...ame flange For module series equipped with a water drain corner clamp must not be applied directly on Please refer to the table on next page showing the different installation options from SOLUXTEC s...

Page 10: ...afety factor of 1 5 With Clamps DMP DMM DMMIV DMMX DMMIVPG DMMXPG PSMVI PSMVIPG Test 8100 2400 Design 5400 1600 Test 2400 2400 Design 1600 1600 Test 8100 2400 Design 5400 1600 Test 2400 2400 Design 16...

Page 11: ...With Mounting Holes DMP DMM DMMIV DMMX DMMIVPG DMMXPG DMMIV DMMX DMMIVPG DMMXPG GEMINI Test 8100 2400 Design 5400 1600 Test 8100 2400 Design 5400 1600 Test 2400 2400 Design 1600 1600 Y 410 X 200 X 50...

Page 12: ...solution supplier for the set PV module mounting system clamp system All accessories such as bolt screws and other metal parts are corrosion proof and exempt of any chemical reaction with the frame of...

Page 13: ...in a good shape The final wiring conception is determined in relation to the final project on site Modules deployed for a given project should present the same technical characteristics to prevent an...

Page 14: ...e need to consider the voltage open circuit and the minimal temperature on site You can calculate it with the following formula 1 25 Where N number of modules in serial Uoc Open circuit voltage of a m...

Page 15: ...a fire departure This point is extremely important All framed modules need to be connected together with a grounding solution to the main equipotential bonding of the project location On each module...

Page 16: ...company having realised the installation in order to control the efficiency of the complete generator Dust or pollution from the environment may gather on the surface of PV modules Hence it is recomme...

Page 17: ...17 SOLUXTEC USER GUIDE 2021_Version 1 a_ALL RIGHTS RESERVED SOLUXTEC GmbH Werner von Siemens Str 25 D 54634 Deutschland HRB Wittlich 41318 info soluxtec de...

Reviews: