The private central sometimes

 

deteriorates the rejec-

tion of the hybrid, reason why we advised to directly 
connect the console to the public lines, whenever it 
is possible. 

The  

associate  telephones

  (used  generally by  the 

Production   to   answer   the   calls)   are  

connected   in 

parallel to the lines 

in an external box to the conso-

le; or by means of RJ11 type “Y” adapters.

The telephone lines internally are protected against 
lightings

 

by metallic oxide  varistors  (SIOV). Never-

theless, we recommend to use additionally external 
line protection of good quality. 

 

Although the console has internal protection; it is re-
commended to use external line a protection against 
transient voltage peaks due to accidents or lightings. 

2.2.6.2 CONNECTING A CELL PHONE

An  

adapter cable-interface

  is required to connec-

ting the CELL PHONE to the console. This connecti-
on differs according to brand

 

and model of the cellu-

lar.

 

The following image

 

shows

 

the cellular to RJ-11 

connection.

Basically,   the

 

cellular   connection

 

uses   a   standard 

“free hands” cable purchased for that cellular model. 
The   console   sends   the   program   signal   to   the   cell 
phone and receives  the  audio  from the cell phone 

that 

enters to the D-816 through the hybrid chan-

nel

. The cell phone works in a mode denominated “4 

wires” different from the telephone lines (2 wires). 

In almost all models, microphone and speaker dis-
connects while the cell phone is used in “free hands” 
mode. Please refers to the user manual of you cell 
phone for details on this way of operation.

D816 allows the user to have cellular and land 
phone lines in conference

2.2.6.3 EXTERNAL HYBRID

The D-816 series has a connector with 

send and re-

turn from external hybrid

“External  Hybrid”  uses  a female  TRS  of  ¼” (Jack) 
that gives signal (PGM send) by “tip” and receives 
signal (return or input to console) by “ring”. 

PGM send is MIX-MINUS, that is to say, it sends all 
the signals of ‘Bus' PGM, with exception of the Re-
turn from Hybrid, to avoid feedback loops. 

The audio from external hybrid enters to the console 
through   the   hybrid   channel.   The   main   FADER   will 
behave in the same way that with the telephone lines 
connected to the console, sending the signal to the 
air or the previous circuit, according to the fader po-
sition.

Connection to a computer

This I/O can be used to connect a computer to use a 

VoIP software (like Skype or similar). External Hybrid 

connects to the computer to the microphone input and 

to the line outputs, with a special “Y” cable (¼” TRS to 

two 1/8” TRS). See connection below.

TRS 1/4” to 

D816

TRS 1/8” to the PC 

line output

TRS 1/8” to the PC 

line/mic input

Sleeve

Sleeve 

Sleeve 

Ring (input)

to Tip (Ring N/C)

--

Tip (output)

--

to Tip and Ring

SOLIDYNE

D·816

 broadcast console

Page 11

Summary of Contents for D 816

Page 1: ...Buenos Aires Argentina Phone 54 11 4702 0090 e mail info solidynepro com Fax 54 11 4702 2375 Web site www SolidynePRO com USB INPUTS OUTPUTS DIRECT HARD DISK RECORDING ON AIR compact console User s m...

Page 2: ...Page 2 D 816 broadcast console SOLIDYNE...

Page 3: ...ER 3 Using the console 15 3 1 Overview 15 3 1 1 Quick checking 15 3 2Using the hybrid channel 16 3 2 1 Operation 16 3 2 1 1 Use with a CELL PHONE 16 3 2 2 Return to phone line 17 3 2 3 Rejection setup...

Page 4: ...Page 4 D 816 broadcast console SOLIDYNE...

Page 5: ...put Four LINE channels allow connecting up to 8 sour ces Channels 4 and 5 manages balanced analogical inputs whereas channels 6 and 7 are digital with di rect connection to the computer via USB ports...

Page 6: ...hen opening the channels MIC 1 and or MIC 2 channel MIC 3 does not activate the tally since it can operate as line or microphone The LOAD DOES NOT HAVE TO EX CEED the 120 mA two Solidyne AIR lights If...

Page 7: ...of equipment s to the AC line the seconds ones are generated by communications transmitters or industrial equipment If these signals penetrate into audio lines with sufficient intensity can surpass th...

Page 8: ...s and out puts connectors Take in mind that good connections offer safe and free of faults operation By this reason we recommend you take it the time necessary to make the connections care fully and u...

Page 9: ...uter in digital format the program and recording outputs please see 2 2 3 2 USB Outputs VERY IMPORTANT USB 7 CANNOT BE USED IF CHANNEL USB 6 IS NOT CONNECTED since it is slave of channel 6 In order to...

Page 10: ...in level control or as a more professional solution to mount a control on the speaker s table A potentiometer of 2 x 1KOhm will be right to manage the level In this case the level control of the conso...

Page 11: ...ode denominated 4 wires different from the telephone lines 2 wires In almost all models microphone and speaker dis connects while the cell phone is used in free hands mode Please refers to the user ma...

Page 12: ...s of the console There are three signals of control channels of mi crophone 1 and 2 they handle the same output channel Line 5 and Line 6 These three control outputs are of open collector type They wo...

Page 13: ...SOLIDYNE D 816 broadcast console Page 13...

Page 14: ...2 2 10 Recommended grounding for a FM station Page 14 D 816 broadcast console SOLIDYNE...

Page 15: ...E level unbalanced Then it can be used as MIC or LIN input The three microphone channels can be routed to the processing stage 4 bands EQ and compressor with independence The analog line channels mana...

Page 16: ...taken the talk back MIC is sent to both callers You will engage in a dialog in mode half duplex When the private dialog finalizes you can raise the fa der HYBRID towards the position HOLD that sends...

Page 17: ...we keep a high grade of excel lence in the audio quality of the hybrid on air sound And that quality do not depend on the operator set tings Note that the Solidyne Hybrid on air audio qua lity of the...

Page 18: ...cell phone The D 816 allows maximum flexibility to generate a virtual forum between journalists and interviewees very far apart For this proceed as follows 1 Keep the controls like previous descripti...

Page 19: ...t will be listened in monitors and headphones The assignments for Studio and Control Room are independent The options are PGM to listen the console output REC allows the listening of the channels that...

Page 20: ...ol Room monitors will be muted to avoid feedbacks loops Your voice will be listened inside the Studio by the left channel The right channel stays with the on air audio so that speakers and journalists...

Page 21: ...processor stage EQ with both buttons released If both buttons are pressed the signal is only sent to PGM Enable disable the phantom power 48V for all mic channels Main fader To enable the microphones...

Page 22: ...er below this level the signal from the previous stage must be very high and the peaks will be clipped 3 4 2 Processing Each MIC channel can be sent directly to the air PGM or the processing stage EQ...

Page 23: ...rams D 816 consoles have two stereo output channels The main channel is denominated Program PGM and used for the On Air signal For recording REC is used You can make recor dings while simultaneously t...

Page 24: ...IGNAL EX CEPT WAVE AND GAIN CONTROL MAIN When the work is finished reset all the controls to the original position to return the console to the nor mal way of operation 3 6 2 Recording calls The D 816...

Page 25: ...ember that the rear connec tors are not designed for daily use avoid connection of headsets directly to console When the operator s changes frequently its headsets use an external pat ch panel to avoi...

Page 26: ...This page was left empty intentionally Page 26 D 816 broadcast console SOLIDYNE...

Page 27: ...control to the minimum and increase the input level up to 18 dBm move the fader until ob tain 4 dBm at the output without visible clipping Increase the gain with the main fader until obtaining 15 dBm...

Page 28: ...t MIC and PGM in the channel under test Enable the module by pressing AIR Set the main fader to 10 dB Change the gain control until obtaining 15 dBm at the console output this is the reference level R...

Page 29: ...ompression ratio 2 dB variation for 15 dB change MIC level Noise MIC input EIN 120 dBu 150 ohms LINE input S N 70 dBA Dynamic range From Line to PGM 90 dBA CD quality Crosstalk PGM REC 65 dBA 1 kHz Di...