Page A-4
X-Rack Owner’s Manual
A.3.4 Instrument Input Performance
Un-balanced signal applied to Instrument Input and measured at Output. Pad switched out and Input
Gain control set to +12dB (minimum).
Gain
Continously variable from +12dB to +75dB
Independently switchable 18dB Pad available
Input Impedance
1M
Ω
Output Headroom
> +26dBu at onset of clipping
THD + Noise
< 0.03% at 1kHz
(-18dBu applied, +28dB gain)
< 0.05% at 10kHz
Frequency Response
+0.05dB/-0.1dB from 20Hz to 20kHz
–3dB at 150kHz
Equivalent Input Noise
< –82dB at +12dB (minimum) gain
(Input terminated with 150
Ω
)
< –88dB at +28dB gain (mid’ position)
A.3.5 Line Input Performance
Signal applied to Line Input and measured at Output. Input Gain control set to 0dB (indent).
Gain
Continuously variable from –20dB to +20dB
Input Impedance
> 10k
Ω
THD + Noise
< 0.005% from 20Hz to 20kHz
(+24dBu applied, 0dB gain)
Frequency Response
±0.1dB from 20Hz to 20kHz
–3dB at 150kHz
Equivalent Input Noise
< –90dB
(Input terminated with 150
Ω
)