C
ONNECTION
D
IAGRAM FOR
C
LIENT
U
NITS
C
ONNECTION
D
IAGRAM FOR
B
ASE
S
TATION
Please note that the POE/PS units are different for client units and base station and you must
take care to plug in the right CAT5 cables into the POE/PS unit’s RF-45 ports.
•
P
ORT TO THE RADIO UNIT IS INDICATED BY
“PWR
LAN-OUT”
OR
“DATA
+
PWR
OUT”
•
P
ORT TO THE PREMISE SWITCH OR COMPUTER IS INDICATED BY
“LAN-IN”
OR
“DATA-IN”
C.
I
NITIAL
L
OGON
•
Open
networking properties
in your Windows OS. Enter the TCP/IP setup window of your
wired Ethernet adapter properties page. Set the IP addresses to the following values.
Ethernet’s IP Address:
192.168.1.1
Subnet Mask:
255.255.255.0
•
Open a Web Browser on the Test PC
•
At the URL line, type in the following:
http://192.168.1.100
to access a client unit, or
http://192.168.1.200 to access a base station unit.