© CASWA Pty Ltd – 2013
6 | Page
2.3
Electrical Specifications
Parameter
Description
Min
Typ
Max
Units
V
in
Supply voltage
24
12
250
48
VAC
VDC
I
in
Supply current
40
100
mA
V
limit
Overload relay voltage
60
VAC
I
limit
Overload relay current
0.5
2
V
V
limit
Limit Switch input voltage
60
VAC
L
sense
mv load sensor sensitivity
0.5
10
mV/V
R
in
Input impedance of 0-10V input
1500
Ohms
I
24
24V output current
100
mA
Operating temperature
-40
85
Note 2
°C
Notes:
1.
Power supply –ve and GND pins are at chassis GND (0V) potential
2.
Extended operation at maximum temperature will reduce the life the device.
2.4
Communication Specifications
Communications between the device and a host is usually via a Bluetooth radio link. The Bluetooth
device name will be set to the Crane ID, the PIN is 0000.
For more details on the communication protocol used to communicate with the Liftlog™XL, see
Appendix A.