© CASWA Pty Ltd – 2013
29 | Page
4.10.2
Reformat SD Card
If necessary, it is possible to delete all loading history from the LiftlogXL device by formatting the SD
card. A typical example of where this is useful is when the test process has not been successful, or if
the data logger is moved from one crane to another and prior data on the device is no longer
applicable.
Configuration and load calibration settings are not affected by reformatting the card. To
delete/change these settings, go to sections 4.5 through 0 of this manual.
Hint:
Prior to reformatting, it is recommended that data be downloaded from the device as detailed
in section 4.5.2.
To erase the onboard memory card, press the <Reformat Card> button. You will be asked to confirm
the action.
4.11
Running CheckIt Diagnostics
To confirm whether critical settings and parameters have been set sensibly, after completing the
setup and commissioning of the Liftlog™XL device, it is strongly recommended that you run CheckIt
diagnostics (first introduced in version 11.9 of the FSU application).
To initiate CheckIt Diagnostics, go to the General
Tab and click on the check box in the lower left
corner of the tab:
A new window will appear and CheckIt Diagnostics will be initiated.
During this process you may be asked to enter parameters (e.g. rated capacity of the hoist) to verify
that critical settings have been entered and have saved correctly.
Any potential issues or irregularities will be described in the CheckIt Diagnostics window. A
summary of these will also be sent to the server for future reference.
Press <Close> to return to the main FSU screen.