d) Export control
With this function the inverter can control energy exported to the grid.
Whether having this function is based on user’s wishes.
Choose ”Enable” in ”Enable/Disable” means user must install a meter to
monitor energy exported to the grid. There are user value and factory value.
The factory value is default which can not be charged by user. The user value
setting by installer must be less than the factory value and within the range of
0KW to 20KW.
Choose”Disable” means the function will be shut off.
Press up and down button to select and press”OK” to confirm.
b) Date time
This interface is for user to set the system date and time. Increase or decrease
the word by pressing up or down button. Press OK to confirm and alternate
to next word. After all the words are confirmed. Press “OK” to enter the date
and time.
﹦﹦﹦﹦
Date time
﹦﹦﹦﹦
2016 >06 <06
10 19
c) New Password
Installer can set the new password here. We need to increase or decrease the
word by pressing up or down button. Press OK to confirm and alternate to
next word. After word is confirmed., press “OK” to reset the password.
﹦﹦﹦
New Password
﹦﹦﹦
1 2 3 4
34
35
Operation Method
Operation Method
e) RF Control
RF Control is an optional function which can control designated load
intelligently by consuming the surplus energy when feed in power reaches
certain value.
For specific operation, please refer to “ Load remote control installation guide”.
RF Control
>Load1 setting
>Load2 setting
f ) DRM Function
User can choose whether using the DRM function or not.
﹦﹦﹦
DRM Function
﹦﹦﹦﹦
>Enable/Disable
Disable
g) Line Impedance
If able is choosen, the inverter will identify actively the imdepance between
the inverter and grid, and reduce the effect on input port of the inverter. This
function is disable by default.
﹦﹦﹦﹦
Line Impedance
﹦﹦﹦﹦
>Enable/Disable
Disable
h) Grid Services
Usually end user do not need to set the grid parameters. All default value have
been set before leaving factory according to safety rules.
If need to reset, any changes should according to the requirement of local
grid.
>Enable/Disable
Please enter setting and disable “netural line” if there is no netural
cable in the wiring.
WARNING
!