4. Installation
4. Installation
22
23
2. After all the battery modules were correctly connected, plug the short-circuit
plug (F) at YPLUG (
Ⅴ
’) of last battery module to make a complete circuit.
Danger!
Touch the two sheetmetals of the power connector will get an electirc
shock, DO NOT touch them! Also DO NOT connect XPLG to YPLG on the
same battery module!
X
Capacity
4.5.2
Connecting RS485 Communication Cable
For one battery module:
1. There's a protective cap for the RS485 connector, unscrew the cap and plug
one end of the RS485 communication cable to the RS485 connector on BMS.
Tighten the plastic screw cap with rotation wrench(I).
2. C
onnect the RS485 communication
c
able (E) from BMS (
Ⅲ
) to the RS485 I
communication port (
Ⅱ
’) on the battery module. The communication ports are
marked in the following figure.
For 2~4 battery modules:
Follow the same steps as the above.
Then Connect RS485 II (
Ⅳ
’) of first battery module to RS485 I (
Ⅱ
’) of the next
battery module. Repeat the same step to connect the rest battery modules.
Sequence
1
2
3
4
5
6
7
8
RS485I
RS485II
VCC_485
VCC_485
GND_485
GND_485
B2
B2
N-
N-
P+
P+
A2
A2
VCC_485_2
VCC_485_2
GND_485
GND_485
The wiring order of the communication cable is as follows:
1 2 3 4 5 6 7 8
1) White with an orange stripe
2) Orange
3) White with a green stripe
4) Blue
5) White with a blue stripe
6) Green
7) White with a brown stripe
8) Brown