1. Shut down the T-BAT system (Please refer to
Section 5.4 Shutting Down
T-BAT System
of User Manual on Page 33);
2. Remove the lock cover
a. Pull at back end of the lock cover with nger or an instrument;
b. Remove the lock cover and keep it for next time.
DO NOT plug/unplug power cables when the T-BAT system is not turned off,
otherwise there will be an arc discharge that could cause serious injury!
+
-
+
-
Lock Cover
3. Push the plastic button on each end of the power cable in the direction
of the arrow;
4. Unplug the power cable.
Notes for Unplugging Power Cables
CAUTION!
4. Installation
4. Installation
20
21
For 2~4 battery modules:
The power cable between battery modules (A1) is different from the one that
between BMS and battery module ©. The other end of the power cable is black,
and this color is connected to YPLG (
Ⅴ
’), which is on the right side of the battery
module.
1. Plug one end of the 400mm power cable into the YPLUG port(
Ⅴ
’) on the first
battery module, and the other end into the XPLUG port on the next battery
module(
Ⅰ
). Repeat the same step on all the battery modules. The following
figure shows how the four battery modules are connected.
YPLUG
YPLUG
XPLUG
XPLUG
Capacity
NOTE!
Make sure that GND has been finished before the cable connection!
EARTH BAR