P Position
duration
Function
Comments
Switch moved to
P for
less than 5
seconds
Boost Mode
- the device
delivers maximum power to
operate the immersion heater
in full capacity for one hour.
When the switch is released all
LEDs turn OFF for 0.5 sec and
then display the production or
error indication.
Switch moved to
P for
less than 5
seconds
,
while in
Boost Mode
The device stops power supply
to immersion heater.
Switch moved to
P for
5-10
seconds
Starts pairing (association) of
the device with the inverter.
The inverter provisions,
controls and connects the
device to the monitoring
platform.
Re-associating the device loads
the previous configuration so
re-configure is not required.
Association is indicated by all
LEDs blinking.
Switch moved to
P for
30 seconds
Factory reset - disconnects the
device from the inverter
After reset, association with
the inverter is required.