Chapter 6: User Interface
SolarEdge Installation Guide – MAN-01-00002-1.7
43
Server Communication Status Window
S e r v e r : L A N < S _ O K >
S t a t u s : < O K >
x x x x x x x x
< E R R O R M E S S A G E >
Server
: The method of connection to the SolarEdge monitoring server
S_OK
: The connection to the SolarEdge monitoring server is successful (should appear only if the
inverter is connected to the server).
Status
: Displays OK if the inverter established a successful connection and communication with the
specified server port/device (LAN, RS485 or ZigBee module).
xxxxxxxx
: Eight-bit Ethernet Communication Connection Status: A string of 1s and 0s is displayed. 1
indicates OK, 0 indicates an error. Refer to
the possible errors and how to troubleshoot them.
Error message
, according to failure
Refer to
on page 51 for detailed information.
IP Status Window
This window describes the Ethernet configuration: IP, Mask, Gateway and MAC address (Media Access
Control) of the inverter.
I P 1 9 2 . 1 6 8 . 2 . 1 1 9
M S K 2 5 5 . 2 5 5 . 2 5 5 . 0
G W 1 9 2 . 1 6 8 . 2 . 1
M A C 0 - 2 7 - 0 2 - 0 0 - 3 9 - 3 6
ZigBee Status Window
This window describes the ZigBee configuration:
P A N : X X X X X
C h : X X / X X X X R S S I : < L >
I D : X X X X X X X X
M I D : X X X X X X
RSSI
: The receive signal strength of the closest ZigBee in the SolarEdge system. L = low, M = medium,
H = high and - = no signal.
PAN ID
: The ZigBee module pan ID
Ch
.: The ZigBee module channel
ID
: The ZigBee module ID
MID
: The ID of the coordinator (master) ZigBee module. This field is shown only in devices with
router (slave) ZigBee modules. This field appears after a successful ZigBee association. If a ZigBee
module is not connected, a
No ZigBee
message is displayed instead of the
MID
field.