Chapter 6: User Interface
SolarEdge Installation Guide – MAN-01-00002-1.7
38
A list of countries is displayed. If no country is configured, the value is
<NONE>
.
NOTE:
If an inverter is not configured to any country, it will not produce energy.
A
+
near the country indicates that another menu will be displayed after selection.
The following list appears when USA+ is selected.
A u t o
2 0 8 V
2 4 0 V
2 0 8 V N o N e u t r a l
2 4 0 V N o N e u t r a l
2 7 7 V
H a w a i i A u t o
H a w a i i 2 0 8 V
H a w a i i 2 4 0 V
H a w a i i 2 0 8 V N o N
H a w a i i 2 4 0 V N o N
H a w a i i 2 7 7 V
When the Auto option is selected, the inverter automatically detects whether a 208VAC, a 240VAC or
a 277VAC grid is used. Refer to Figure 1 on page 9 to determine when the Auto option may be used:
Inverters framed with a border and that have their Neutral line connected can be set to Auto.
When an option with
No Neutral
is selected, connection to Neutral line is not required. For any other
option, you must connect the Neutral line.
2
Confirm your country selection in the confirmation screen: Toggle to
YES
and press
Enter
.
Language
Select the
Language
option to set the language in which the LCD should display.
Communication
1
Select the
Communication
option to define and configure the communication option used by the
inverter to communicate with the SolarEdge monitoring server and the communication option used
to communicate between multiple inverters.
2
Select
Server
to set which communication method is used to communicate between the inverter and
the SolarEdge monitoring server. Refer to
Chapter 7: Setting Up Communication
description of these communication options.
NOTE:
This menu shows only the communication options installed in the inverter.
3
The following shows a hierarchical tree of the menu options in the
Communication
menu. For
detailed information about all the configuration options refer to the
Communication Options
Application Note
, available on the SolarEdge website at