SETTING THE REQUIRED D. H. W. TEMPERATURE
You can set the required d. h. w. temperature with this button. The controller
heats d. h. w. in accordance with the time program.
Temperature of the d. h. w. can be set between 30 and 70 °C. You can turn the heating OFF,
or turn it ON independent from the time program.
Working thermostat on the boiler must be set on a temperature that is at least
10 °C higher than the preferred d. h. w. temperature.
AUTOMATIC SETTING OF THE REQUIRED NIGHT TEMPERATURE
You can set the automatic setting of the required night tempetaure by
turning the nighttime temperature setting button to the position “AUT”.
Due to the heat accumulation, the nighttime room temperature is usually
higher than the required temperature setting. It is important, that the building
is adequately heated even at that time, especially when the outdoor tempera-
ture is very low.