background image

Operation manual of solar water controller SR530C8/SR530C8Q 
 

 

--------------------------------------------------------------------------------------------------------------------------------------------------- 

- 38 - 

 
 
 

 

 

6.2 Trouble checking 

The  controller  is  quality  product,  conceived  for  years  of  continuous  trouble-free 
operation.  If  a  problem  occurs,  the  cause  of  the  problem  very  often  lies  not  in  the 
controller  but  in  the  peripheral  components.  The  following  description  of  some 
well-known problems should help the installer and operator to isolate the problem, so 
that the system can be place back into operation as quickly as possible and to avoid 
unnecessary costs. Of course, not all possible problems can be listed here. However, 

Error message 
on LCD screen 

Meaning 

Cause of error 

Error rectification 

 
                 

T0    - - - 

 

T0 sensor problem 

Sensor wiring interrupted, 
not connected or short 
circuit 

Check resistance 
value, replace 

Thermal 
measuring 
function is 
switched-on 

T0 sensor not connected   

Connect T0or 
switch-off this 
function 

OHQM

 

 
                 

T1    - - - 

 

T1 sensor problem 

Sensor wiring interrupted, 
not connected or short 
circuit 

Check resistance 
value, replace 

 
               
 

T2    - - - 

 

T2 sensor problem 

Sensor wiring interrupted, 
not connected or short 
circuit 

Check resistance 
value, replace 

 
               
 

T3    - - - 

 

T3 sensor problem 

Sensor wiring interrupted, 
not connected or short 
circuit 

Check resistance 
value, replace 

 
                 

T4    - - - 

 

T4 sensor problem 

Sensor wiring interrupted, 
not connected or short 
circuit 

Check resistance 
value, replace 

hot water 
circulation pump 
function turn-on 

T4 not installing 

Install T4 or 
switch-off this 
function 

Summary of Contents for SR530C8

Page 1: ...cience and Technology Create Perfection Read the instruction carefully please before operation Installation and Operating Manual SR530C8 SR530C8Q Solar Controller For Split Pressurized Hot Water Syste...

Page 2: ...ubmenu 13 4 3 Main menu DT O DT F Temperature difference function 14 4 4 Main menu THET timing heating 15 4 5 TEMP Temperature main menu 18 4 5 1 EM Emergency collector temperature emergency switch of...

Page 3: ...4 6 5 2 tRUN Pump running time 31 4 6 6 BYPR High temperature by pass function tank temperature automatically adjusting 31 4 7 HND Manual mode 32 4 8 PASS Password setting 33 4 9 LOAD Recovery to fac...

Page 4: ...ialists 1 2 About this manual This manual describes the installation function and operation of a solar thermal controller When installing the remaining components e g the solar collectors pump assembl...

Page 5: ...ked the text and pictures of this manual and provided the best of our knowledge and ideas however inevitable errors maybe exist Please note that we can not guarantee that this manual is given in the i...

Page 6: ...compliance with the provisions of the installation For example switch or fuse please note that it should be separated between the wires and use AC power 2 1 Installing the controller Note the control...

Page 7: ...ng installation Depending on the type of installation the cables may enter the device through the rear hole of the case or the lower side hole of the case Cable come from the rear remove the plastic f...

Page 8: ...3 and T4 for NTC10K B 3950 sensors used for measuring the temperature of tank and pipe Advice regarding the installation of temperature sensors Only original factory equipped Pt1000 temperature sensor...

Page 9: ...ntrol max switching current 1A Output R2 for hot water circuit pump electromagnetic relay and max switching current 3 5A R2 ports are always open Output R3 for by pass circuit pump or valve electromag...

Page 10: ...ntroller SR530C8 SR530C8Q 9 Press button to set week Press ESC button to exit set program or wait for 20 seconds to exit program automatically Code Week day MO Monday TU Tuesday WE Wednesday TH Thursd...

Page 11: ...of solar water controller SR530C8 SR530C8Q 10 3 2 Menu structure Menu of controller SR530C8Q Menu of controller SR530C8 Submenu Through submenu customer can set the parameter as desired value please c...

Page 12: ...of collector SMX Maximum temperature of tank REC Tank re cooling function C F Celsius and Fahrenheit temperature transferring FUN Auxiliary function DVW G Anti legionnaires function CIRC Temperature c...

Page 13: ...n as the switch on temperature difference Ton between the collector array T1 and the storage tank T2 is reached If the temperature difference between the collector array T1 and storage tank T2 drops b...

Page 14: ...k for entering password factory default set password is 0000 Press button to enter first digital of password Press SET button again the second digital blinks Press button button to enter second digita...

Page 15: ...ommend to use default set Switch on and switch off DT are alternating set To avoid mistake the minimum difference between two temperature differences Ton Toff is set as 2 o C Setup the switch on tempe...

Page 16: ...ure adjustable range 10 OFF 2 The switch off temperature adjustable range ON 2 80 If you want to shut off one timing heating then you can set the turning on time and turning off time same value for ex...

Page 17: ...n be set Press SET button 05 of hour time blinks on screen Press button to adjust hour of time Repress SET button 00 of minute time blinks on screen Press button to set minute of time Repress SET butt...

Page 18: ...Repress SET button 00 of minute time blinks on screen Press button to adjust minute of time Repress SET button temperature 50 blinks on screen Press button to adjust switch on temperature of heating P...

Page 19: ...the parameters can be adjusted in a solar system Following submenu can be access though TEMP main menu EM Emergency collector temperature Emergency switch off temperature of collector 4 5 1 CMX Maxim...

Page 20: ...temperature adjustable range 120 200 factory set is 130 Repress SET button activate and deactivate this function if deactivate the function EM displays on screen Press ESC button to exit menu or wait...

Page 21: ...MX CMX 110 displays on screen Press SET button parameter 110 blinks Press button to adjust the collector protection temperature adjustable range 100 190 factory set is 110 Repress SET button activate...

Page 22: ...rcuit pump is triggered Besides when tank temperature T2 drops to 4o C electrical heater is triggered automatically and it is in operation until T2 is heated up to 20 o C or it is stopped when program...

Page 23: ...sed even at the case that DT caters condition When tank temperature drops and is 2o C below the SMX solar pump restarts when DT caters condition Setup steps To access main menu TEMP then select submen...

Page 24: ...s on screen Press SET button parameter blinks on the screen Press button to select between Celsius and Fahrenheit temperature factory set is Press ESC button to exit menu or wait for 20 seconds to exi...

Page 25: ...n of anti freezing liquid 6 4 3 INTV Pump interval function 4 6 5 tRUN Pump interval time 4 6 5 1 tSTP Pump running time 4 6 5 2 BYPA High temperature by pass function tank temperature automatically a...

Page 26: ...temperature is 40o C when return temperature T4 drops to 35o C circulation pump R2 is triggered when T4 rises up to 40o C circulation pump R2 is ceased Condition for triggering hot water circulation p...

Page 27: ...teps To access main menu FUN then select submenu nMIN nMIN 30 displays on screen Press SET button parameter 30 blinks on the screen Press button to adjust speed of circuit pump adjustable range 30 100...

Page 28: ...en Press button to adjust increase rate of RIS of temperature difference adjustable range 1 20 factory set is 1o C Press ESC button to exit the menu or wait for 20 seconds to exit automatically parame...

Page 29: ...or 3 seconds buzzer makes 3 times du the daily thermal energy is cleared and daily thermal energy is reset to 00 Press button select to check accumulative thermal energy KWH XX or MWH XX SET displays...

Page 30: ...ycol 03 Tyfocor LS G LS Setup steps To access main menu FUN then select submenu MEDT MEDT 01 displays on screen Press SET button parameter 01 blinks on the screen Press button to adjust type of heat t...

Page 31: ...me is 06 00 20 00 During the period that solar pump is in operating the period of running time can be set by parameter tRUN controlled check the temperature signal of sensor if the temperature increas...

Page 32: ...range 5 120 seconds Press ESC button to exit the menu or wait for 20 seconds to exit automatically parameters are saved automatically 4 6 6 BYPA High temperature by pass function tank temperature auto...

Page 33: ...by pass function is activated 4 7 HND Manual mode When using this controller first time or when debugging this controller output of this controller R1 R2 R3 R4 can be triggered manually On OFF control...

Page 34: ...on displays on the screen R4 output is switched on Repress SET again HND4 off displays R4 output is switched off Press ESC to exit R4 set program Note when manual mode is activated signal displays on...

Page 35: ...20 seconds to exit automatically Warning If the password is forgot it is not possible to recover but you can recover the password to factory set then you can reedit a password like above descript step...

Page 36: ...perature drops 8 o C below the storage tank temperature T2 solar circuit pump starts to work when the temperature of collector is 2o C below the tank temperature and solar circuit pump is ceased Activ...

Page 37: ...ature adjustable range 10 80 factory set is 60 After 20 seconds this function is activated signal displays on the screen and heating signal blinks also Press Heating button again to switch off manual...

Page 38: ...will start the anti dry heating protection EE displays on screen and controller switches off all outputs H1 In this case it ought to switch off power supply check and resolve the problems and then swi...

Page 39: ...en Meaning Cause of error Error rectification T0 T0 sensor problem Sensor wiring interrupted not connected or short circuit Check resistance value replace Thermal measuring function is switched on T0...

Page 40: ...p doesn t operate despite the fact that switch on conditions are satisfied The pump symbol in the display blinks Pump power supply is interrupted Check the pump power cable Pump doesn t operate The pu...

Page 41: ...eviation 1 is acceptable PT1000 resistance value 0 10 20 30 40 50 60 70 80 90 100 110 120 1000 1039 1077 1116 1155 1194 1232 1270 1309 1347 1385 1422 1460 NTC 10K B 3950 resistance value 0 10 20 30 40...

Page 42: ...Suitable power of pump 3 600W 3 600W Suitable power of electrical heater 1 2000W 1 2000W Inputs 2 x Pt1000 sensor 500o C for collector silicon cable 280o C 3 x NTC10K B3950 sensor 135o C for tank PVC...

Page 43: ...llector high accuracy PT1000 sensor A01 Parameter PT1000 6X50mm Sensor for tank high accuracy NTC 10K sensor A02 Parameter NTC10K B 3950 6X50mm Thermowell of sensor stainless thermowell A05 Parameter...

Reviews: