Operation manual of solar water controller SR530C8/SR530C8Q
---------------------------------------------------------------------------------------------------------------------------------------------------
- 28 -
Setup steps:
To access main menu FUN, then select submenu OHQM, “OHQM OFF” displays on
screen,
Factory set is OFF
►Press “SET” button, parameter “OHQM
OFF” blinks on the screen
►Repress “+”“-” button, to activate this
function, “OHQM oN” blinks on the screen
► Press “ESC” button to exit the menu or wait for 20 seconds to exit automatically,
parameters are saved automatically.
Note:
1)
Thermal energy achieved in current day, accumulative thermal energy and operation
time of pump can be reset, doing like following
Operation steps:
under standby status, doing like following
►Press “+”“-” button, select to check the thermal energy of current day, “DKWH XX”
“SET” displays on the screen.
►Press “SET” button for 3 seconds, buzzer makes 3 times “du-----“, the daily thermal
energy is cleared, and daily thermal energy is reset to “00”.
►Press “+”“-” button, select to check accumulative thermal energy, “KWH XX” or
“MWH XX” “SET” displays on the screen.
►Press “SET” button for 3 seconds, buzzer makes 3 times “du-----”, the sum thermal
energy is cleared, accumulative thermal energy is reset to “00”.
►Press “+”“-” button, select to check operation time of pump, “hP XX” “SET “displays
on the screen.
►Press “SET” button for 3 seconds, buzzer makes 3 times “du-----”, the operation time
of pump is cleared, and it is reset to “00”.
2)
Only when the thermal energy balance function is activated, operation time of
circulation pump function just can be triggered.
4.6.4.1 FMAX Flow rate
Note: SR530C8 doesn’t have this function
FAMX: Flow rate L/min. adjustable range: (0.1
~
20) L/min, increase rate 0.1L per time,
factory set is 2.0L/min
Setup steps:
To access main menu FUN, then select submenu FMAX, “FMAX 2.0” displays on