Operation manual of solar water controller SR530C8/SR530C8Q
---------------------------------------------------------------------------------------------------------------------------------------------------
- 29 -
screen.
►Press “SET” button, parameter “2.0” blinks on
the screen
►Press “+”“-” button to adjust parameter of flow
rate. adjustable range
(
0.1
~
20
)
► Press “ESC” button to exit the menu or wait for 20 seconds to exit automatically,
parameters are saved automatically.
4.6.4.2 MEDT Type of heat transfer liquid
Note: SR530C8 doesn’t have this function
MEDT: type of heat transfer liquid, adjustable range (00
~
03)
,
factory set
:
01
Type of heat transfer liquid:
00
:
Water
01
:
Propylene glycol
02
:
Glycol
03
:
Tyfocor LS/G-LS
Setup steps:
To access main menu FUN, then select submenu MEDT, “MEDT 01” displays on
screen.
►Press “SET” button, parameter “01”
blinks on the screen
►Press “+”“-” button, to adjust type of heat
transfer liquid, adjustable range (00
~
03
)
► Press “ESC” button to exit the menu or wait for 20 seconds to exit automatically,
parameters are saved automatically.
4.6.4.3 MED% Concentration of heat transfer liquid
Note: SR530C8 doesn’t have this function
MED% Concentration of heat transfer liquid (volume percentage %), depending on the
type of heat transfer liquid, adjustable range (20 ~70), factory set 40%
Setup steps:
To access main menu FUN, then select submenu MED%, “MED% 40” displays on
screen.
►Press “SET” button, parameter “40” blinks on the screen