Operation manual of solar water controller SR530C8/SR530C8Q
---------------------------------------------------------------------------------------------------------------------------------------------------
- 13 -
T0: Temperature sensor for thermal energy measuring ( optional sensor)
T1: Temperature sensor for collector array
T2: Temperature sensor in the bottom part of tank 1.
T3: Temperature sensor in the top part of tank (optional sensor)
T4: Temperature sensor on hot water circulation pipe (optional sensor)
R1: Solar circuit pump
R2: Hot water circuit pump (optional output)
R3: High temperature by-pass pump or valve (optional output)
H1: output for back-up electrical heater
4
.
Controller functions
4.1 Access main menu
Under standby status, doing like following access main menu
►Press “SET” button, “PWD 0000”displays on screen, the left first digital blinks, ask for
entering password, factory default set password is “ 0000”
►Press “+”“-” button to enter first digital of
password.
►Press “SET” button again, the second digital
blinks
►Press “+”“-” button button, to enter second digital of password
►Press “SET” button again, the third digital blinks
►Press “+”“-” button to enter the third digital of password
►Press “SET” button again, the fourth digital blinks
►Press “+”“-” button, to enter the fourth digital of password
►Press “SET” button again to access main menu
►Press “+”“-” button, can select the main menu
►Press “ESC” button to exit main menu
4.2 Access submenu
After selecting main menu, do like following access submenu
►Press “SET” button, to access submenu
►Press “+”“-” button to select submenu
►Press “SET” button again to access program
,
can adjust parameter value now
►Press “+”“-” button, to adjust the value of
parameter
►Press “ESC” button, exit program of submenu
►Press “ESC” button again, to exit main menu.
For example: submenu