![Solaira Malibu MAL 45240 Reference Manual Download Page 13](http://html1.mh-extra.com/html/solaira/malibu-mal-45240/malibu-mal-45240_reference-manual_1313296013.webp)
13
of 20
Ref No. 043477-EN Rev. A
5
. Feeding the supply cable through the heater assembly, pass the cable through the M25
cable gland and through the terminal box. Locate the heater assembly onto the joining
pieces of the body pole assembly. Secure in place with 3 X M8 × 20mm button head socket
screws, placing M8 spring/split washers behind the heads of the screws.
M8 SPRING/SPLIT WASHER
3 - OFF
M8 × 20 BUTTON HEAD
SOCKET SCREW
3 - OFF
6
. Connect the mains supply cable to the connector block and earth post as shown using
ring terminals and keeping the link wires in place as shown. Tighten the strain relief gland
nut fully and replace the terminal box lid and tighten the screws fully to prevent water
ingress.
GROUND
POST
PRE-WIRED
HEATERS SIDE
SUPPLY
CABLE
208/240V
L1 CONDUCTOR (208/240V)
L2 CONDUCTOR (208/240V)
GROUND
CONDUCTOR
INCOMING
SUPPLY CABLE
208/240V
LINK WIRES
L1
L2
L1
L2