PRODUCT FEATURES
22
HYD 5K...20KTL-3PH
3.5.5
System with multiple inverters (5
–
200 kW)
Up to 10 inverters can be connected in parallel, to the grid and EPS
connections, resulting in an EPS output of up to 200 kVA.
NOTE
•
The inverters connected in parallel should have the same
power and battery configuration.
•
The energy meter or CTs are connected to the Master
inverter. Control of all inverters takes place via the link
cable.
•
For the parallel switching of several devices, it is
recommended to use a joint AC load break switch for the
connected loads at the LOAD connection.
•
For the parallel switching of several devices, it is
recommended to use a joint AC load break switch for the
connected loads at the GRID connection.
AMASS-
Storage
Battery
Normal Load
WiFi/GPRS
,
RS485,USB,CAN2.0
Grid
Critical Load
Power Generation Date
Monitoring Platform
AMASS-
Storage
Battery
Up to 10*Inverters Parallel
Connection
Hydbrid Inverter
Primary
Hydbrid Inverter
Replica
PV panels
PV panels
Smart Meter