SOFAR 3K~6KTLM-G3
User manual
Copyright © Shenzhen SOFAR SOLAR Co., Ltd
- 54 -
ID018
HwADFaultDCI
Wrong sampling of dc
component
of
grid
current
ID019
HwADFaultVGri
d(DC)
Power grid voltage
sampling error (DC)
ID020
HwADFaultVGri
d(AC)
Power grid voltage
sampling error (AC)
ID021
GFCIDeviceFault
(DC)
Leakage
current
sampling error (DC)
ID022
GFCIDeviceFault
(AC)
Leakage
current
sampling error (AC)
ID023
HwADFaultDCV
Error in dc component
sampling
of
load
voltage
ID024
HwADFaultIdc
Dc
input
current
sampling error
ID029
ConsistentFault_
GFCI
Leakage
current
consistency error
ID030
ConsistentFault_
Vgrid
Grid
voltage
consistency error
ID033
SpiCommFault(D
C)
SPI
communication
error (DC)
ID034
SpiCommFault(A
C)
SPI
communication
error (AC)
ID035
SChip_Fault
Chip error (DC)
ID036
MChip_Fault
Chip error (AC)
ID037
HwAuxPowerFau
lt
Auxiliary power error
ID041
RelayFail
Relay detection failure
ID042
IsoFault
Low
insulation
impedance
Check the insulation resistance
between the photovoltaic array and
ground (ground), if there is a short
circuit, the fault should be repaired in
time.
ID043
PEConnectFault
Ground fault
Check ac output PE wire for
grounding.
ID044
PV Config Error
Error
setting
input
mode
Check
the
PV
input
mode
(parallel/independent mode) Settings
for the inverter. If not, change the PV
input mode.
ID045
CTD isconnect
CT error
Check whether the CT wiring is
correct.
ID049
TempFault_Bat
Battery
temperature Make sure the inverter is installed