- 48 -
country setting through LCD (default: 0001), country setting can be set in 24h
after keying in the correct passwords, over 24h, set through LCD again.
7. Set Energy
Set the total power generation. You can modify the total power generation
through this option.
8. Set address
Set the address (when you need to monitor multiple inverters
simultaneously)
,
Default 01.
9. Set Input mode
SOFAR 3K-6KTLM-G2 has two MPPT channels, which can run
independently or in parallel. Users choose the operation mode of MPPT
according to the system design. Parallel mode is applicable to the case where
two channels are in parallel, independent mode is applicable to the case where
two channels of MPPT run independently, and the default mode is independent
mode.
10. Set Language
Set the inverter display language.
Easier Way: press
“
Back
”
&
“
OK
”
at the same time to change system
language.
11. Set Start Parameter
12. Set Safety Voltage
13. Set Safety Frequency
14. Set Insulation
User can modify the above 4 parameters of the machine through the SD
card, and the user needs to copy the parameter information that needs to be
modified into the SD card in advance.
Note: To enable this feature, please contact the Sofarsolar technical support.
15. Set Reactive
Enable or disable reactive functions.
16. Set Power Derate