SOFAR 3K~6KTLM-G2
User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd
- 40 -
RS485
→
USB adapter; connect the USB port of the adapter to the computer. A
maximum of 31 inverters can be connected in one daisy chain. (NOTE2)
Figure 4-35
2. WI-FI/GPRS/Ethernet
Refer to the figure shown below: (wireless function required for the PC).
Figure 4-36
The operation information (generated energy, alert, operation status) of the
inverter can be transferred to PC or uploaded to the server via
WIFI/GPRS/Ethernet. You can register on the website.
http://www.solarmanpv.com/portal/Register/Regi_Pub.aspx
Using the Wi-Fi/GPRS/Ethernet S/N number (NOTE3), then you can login
the website:
http://www.solarmanpv.com/portal/LoginPage.aspx
to remote
monitors the inverter.
Note1:
The length of the RS485 communication cable should be less than 1000 m.
Note2:
When multiple inverters are connected via RS485 wires, set mod-bus address to
differentiate the inverters.