SOFAR 7K~10.5KTLM-G3
User manual
Copyright © Shenzhen SOFAR SOLAR Co., Ltd
- 55 -
7. Trouble shooting
Outlines of this chapter
This topic describes how to perform daily maintenance and troubleshooting to
ensure long term proper operation of the inverter.
7.1. Trouble shooting
This section contains information and procedures for solving possible problems
with the inverter.
This section help users to identify the inverter fault. Please read the
following procedures carefully:
Check the warning, fault messages or fault codes shown on the inverter
screen, record all the fault information.
If there is no fault information shown on the screen, check whether the
following requirements are met:
- Is the inverter mounted in a clean, dry place with good ventilation?
- Is the DC switch turned ON?
- Are the cables adequately sized and short enough?
- Are the input and output connections and wiring in good condition?
- Are the configuration settings correct for the particular installation?
- Are the display panel and the communication cables properly connected and
undamaged?
Follow the steps below to view recorded problems:Long press the button to enter
the main menu from the standard interface. Select “ 2. Event List ” then long
press the button to enter event list.
Earth Fault Alarm
This inverter complies with AS/NZS 5033 for earth fault alarm monitoring.
If an Earth Fault Alarm occurs, the fault will be displayed on the LCD screen,