SECTION 3
EMERGENCY PROCEDURES
SOCATA
MODEL TB 20
The content of this document is the property of
socata
. It is supplied in
confidence and commercial security of its contents must be maintained.
It must not be used for any purpose other than that for which it is supplied, nor
may information contained in it be disclosed to unauthorized persons. It must not
be reproduced nor transmitted in any form in whole or in part without permission
in writing from the owners of the Copyright.
Information in this document is subject to change without notice.
© 1988, 1991, 1992, 1994 to 1996, 1997, 2000 -
socata
- All rights reserved
June 30, 1988
Revision 8
3.9
* If FIRE is in CABIN :
Main switch
OFF
”ALTr FLD” switch–breaker
OFF
All electrical switches
(except magnetos)
OFF
Cabin air cooling & demisting
FIRE CUT–OFF
Fire extinguisher (if installed)
ACTIVATE
* If FIRE APPEARS TO BE OUT and electrical power is
necessary to continue flight :
Main switch
ON
Circuit breakers
CHECK for faulty circuit,
do not close
Radio/electrical switches
ON, one at a time
Cabin air cooling
OPEN when fire is out
CABIN FIRE
Main switch
OFF
Cabin air cooling & demisting
FIRE CUT–OFF
Fire extinguisher (if installed)
ACTIVATE
WARNING
AFTER DISCHARGING A FIRE EXTINGUISHER
WITHIN A CLOSED CABIN, WHEN FIRE IS
EXTINGUISHED, PARTIALLY OPEN CABIN AIR
COOLING TO VENTILATE THE CABIN AND
PREVENT SUFFOCATION
Land as soon as possible.
WING FIRE
Navigation and landing lights
OFF
Anticollision lights (if installed)
OFF
Pitot heating (if installed)
OFF
Land as soon as possible.