Lit. No. 74256, Rev. 02
23
February 15, 2020
TROUBLESHOOTING GUIDE
Problem
Possible Cause
Suggested Solution
Motor does not run.
Unplug the spreader harness and tag out, if required,
before performing any of the following repairs.
1. Electrical connections are loose.
1. Open access cover and check motor,
harness, and module connections.
2. Blown fuse.
2. Replace spreader vehicle battery
cable fuse.
3. Motor seizes.
3. Replace motor.
Material does not
fl
ow.
Unplug the spreader harness and tag out, if required,
before performing any of the following repairs.
1. Obstruction in hopper.
1. Clear obstruction.
2. Material is bridged.
2. Clear the bridged material or adjust
the ba
ffl
e extension.
3. Auger is loose on shaft.
3. Align auger with
fl
at machined area
on shaft and tighten locking bolt on
side of auger.
4. Auger runs backward.
4a. Check the wire connections at the
P–FEED–N posts on the spreader
module. Auger harness RED to
P–FEED; auger harness BLACK to
FEED–N.
4b. Check that auger motor harness is
correct part number for spreader
model.
5. Material is wet.
5. Replace with dry material.
6. Material is coarse or frozen.
6. Replace material.
7. Spinner does not turn.
7. Check connection inside motor
enclosure.
Material free
fl
ows.
1.
Incorrect ba
ffl
e length.
1a. Install correct ba
ffl
e.
1b. Adjust the ba
ffl
e extension.
2. Ba
ffl
e does not touch hopper on
three sides.
2. Reposition ba
ffl
e.
Vibrator does not work.
1. Electrical connections are loose.
1a. Check the vibrator to harness
connection.
1b. Check vibrator harness to module
connections (BAT, GND, and
blue bullet connector).
2. Blown fuse.
2. Open access cover to replace fuse
in the fuse holder on the vibrator
harness.
3. Vibrator failure.
3. Replace vibrator.
Summary of Contents for V-Pro 32200
Page 2: ......