background image

 

Information  regarding  the  WARNING  and  CAUTION 
designations used in this instructions manual 
 

 WARNING: Indicates conditions which may lead to 

death  or  serious  injury  of  the  user  if  the  product  is 
mishandled. 
 

 CAUTION: Indicates conditions that can be expected 

to lead to the risk of injury to the user or the occurrence 
of physical damage to property. 
 
CAUTION: The auto-igniters may be difficult to ignite 
in high altitudes and at low temperatures. If you are in 
the mountains or camping, be sure to bring matches or a 
lighter (non-electric), just in case. 

■ Table of Contents 

Product Features 

Safety Precautions 

Contents of Set (Names of Parts)  

Assembly and Use 

 
Precautions for Use 

13 

Inspection and Care 

13 

After-Sale Services 

13 

How to Spot and Handle Malfunctions and Abnormalities 

14 

Specifications 

15 

 

GigaPower Standard Double Burner Stove (GS-220) 

The liquefied petroleum gas inside the canister is extracted in gas form and combusted. 
 
High-Power Designated Exclusive Snow Peak Products 
 
GigaPower Gas 500 Iso Fuel (GP-500) | White background with silver band 
GigaPower Gas 500 ProIso Fuel (GP-500G) | White background with gold band 
 
Please be sure to use these products. 

 

 

 

 

Designated Exclusive Snow Peak Fuel Canisters 
 
GigaPower Gas 500 ProIso Fuel (GP-500G) | White background with gold band 
GigaPower Gas 500 Iso Fuel (GP-500S) | White background with silver band 
 
Please be sure to use these products. 
 
<CAUTION> 
It is dangerous to use any fuel canisters other than these designated exclusive ones. Even 
these  designated  exclusive  canisters  will  heat  up  if  stored  in  a  high-temperature 
environment, causing their internal pressure to increase and resulting in the emission of 
large flames, so do not place your face or hands near the burner. Take sufficient care 
when storing fuel canisters, and only use fuel canisters that have been stored in a hot 
environment after they have cooled down. 

 

 

For safety purposes, always ignite from the LO setting, and then gradually increase while monitoring the heat. 

 
 

 

Liquid fuel 

Gas fuel 

White 
background with 
gold band 
White 
background with 
silver band 

Summary of Contents for GigaPower GS-220

Page 1: ...r Double Burner Stove Liquid Injection GS 230 Instructions and precautions that are specific to this product are displayed in boxes outlined with thick solid lines like this GigaPower Double Burner St...

Page 2: ...GS 230 Turning the canister upside down results in the liquefied petroleum gas inside being injected as is in liquid form for combustion Unlike devices designed to extract and combust the fuel in gas...

Page 3: ...ted High Power Designated Exclusive Snow Peak Products GigaPower Gas 500 Iso Fuel GP 500 White background with silver band GigaPower Gas 500 ProIso Fuel GP 500G White background with gold band Please...

Page 4: ...RNING For GS 230 Attachment and detachment of the fuel canister is done in an upright connector on top vertical position Never overtighten Liquid remaining in the valve will release when the canister...

Page 5: ...oss multiple stoves Reason If one large cooking tray or pot is heated on multiple stoves the whole assemblage will become extremely hot due to the combined radiant heat causing the stoves and fuel can...

Page 6: ...ter for a long period of time or are moving the stove detach the canister and place the cap on it Reason The heat adjustment knobs on the front of the unit may be accidentally turned on causing a gas...

Page 7: ...ed with precision Modifying them will not only decrease their performance but could also lead to incomplete combustion or gas leakage Consult the store where you purchased this product or Snow Peak re...

Page 8: ...t Double burner main unit Trivet 2 Stand 2 Cover with windscreen Fuel canister valve shield Cover Trivet Stand Auto igniter Heat adjustment knob Stand Fuel canister valve shield Lock spring Trivet Sto...

Page 9: ...sides You can easily remove them by gently pulling them outwards 2 Attaching the stands 1 Remove the trivets stored inside the stove The trivets are detached from the stove There is the risk of the t...

Page 10: ...mage 1 Turn the heat adjustment knobs on the front of the unit clockwise to close the gas valves 2 Detach the connection tube stored on the back surface by releasing it from the hook and rotating the...

Page 11: ...ur hands 4 To detach a fuel canister follow the above procedure in reverse 5 Attaching and detaching the fuel canister and the stove GS 230 Only use designated exclusive Snow Peak fuel canisters Do no...

Page 12: ...r more than two seconds following gas discharge stop using the auto igniters and allow to ventilate until there is no odor of gas We recommend using a long lighter if the auto igniters are not working...

Page 13: ...the stove as well as incomplete combustion If you use a tray on trivets in the low position the protrusions on the trivet will cause tray instability 1 Set the trivets to the high position Remove one...

Page 14: ...ogged due to boil over etc can result in incomplete combustion If you are disassembling a burner head be careful not to twist the generator pipe GS 230 model or the end of the igniter If the generator...

Page 15: ...in low lying areas In the unlikely event that a gas leak occurs do not use until the area has been sufficiently ventilated 14 Remove the fuel canister when the stove is not being used 15 If the ignite...

Page 16: ...uish How to handle Attach the fuel canister according to the instruction manual Use exclusive Snow Peak fuel canisters Replace with a new fuel canister Request inspection Check the attachment of the f...

Page 17: ...BL Designated pot diameter 23cm or lower Volume 8 0L or lower GigaPower Standard Double Burner Stove GS 220 Materials Stainless steel anodized aluminum brass Size When stored 500 110 360mm with windsc...

Page 18: ...and additional damage 1 Turn the heat adjustment knobs on the front of the unit clockwise to close the gas valves 2 Detach the connection tube stored on the back surface by releasing the hook and rot...

Page 19: ...P 500S or GP 500BL CAUTION Always attach and detach fuel canisters only when they are in an upright position connector on top Snow Peak Inc 958 Sanganji Sanjo shi Niigata ken 955 8616 TEL 0256 38 1110...

Page 20: ...pinched while performing these tasks 1 Lower the lock bar and open the locks on the left and right Only open and close the lock with the lock bar Forcefully opening or closing the lock arm could preve...

Page 21: ...AUTION Hold the fuel canister tightly and do not let go when attaching or detaching The impact of a fall or the load on the connection tube from the weight of the fuel canister could cause damage Pres...