18. Turn auger shaft by hand to make sure shaft rotates
easily.
19. Reinstall bushing retainer into flange bushing groove.
20. Reinstall gearcase gasket.
21. Secure cover to gearcase with four external tooth
locking washer bolts.
22. Press a new front cover into gearcase.
23. Add gearcase oil. Oil level MUST be 6.1 cm – 6.7 cm
(2.4" – 2.6") from the flat surface of the gearcase
cover.
IMPORTANT:
Ariens recommends using only Ariens L3
synthetic severe duty gear lube. Using other lubricants will
not automatically void unit warranty, but the warranty will
not cover damage caused by using unauthorized
lubricants. Refer to the Operator’s Manual for your unit for
the service part numbers.
24. Reinstall seal washer (rubber side down) and oil fill
plug. Torque to 9 N•m (80 lb-in). DO NOT over-torque.
Figure 95
Figure 96
Figure 97