3.5 Source Properties
Source Properties for a selected tile can be opened from the Module
→
Setup Source menu,
or by double-clicking on a selected source in the source folder.
3.5.1 Audio Tab
Use the Audio Tab to assign audio channels to sources, make global settings for phase bars
and select reference levels for analogue audio and analogue scales.
Fig 24. Source Properties - Audio Tab.
Audio Mode
Selects the audio source; Embedded (from SDI video), External (from
optional external audio input card), or NGM-164 (audio over LAN).
A list of available servers appears in the drop-down box below).
Channel 1 to 16
Controls
Select an audio input to display for the associated source bar.
Phase Bar 1 and 2
Enable either or both phase bars and select two channels from the
appropriate drop down box.
Reset Button
Press this button to reset all items in Channel/Phase bar drop-down
lists to the first available item (which will be “None” in the list given by
the protocol).
A/D Reference
Set the analogue to digital reference level when applying an
analogue meter scale to a digital source, or a digital meter scale to an
analogue source. It can be set within the range of -30 to -3dBfs.
0 dB Reference
Set the 0dBu reference level with respect to analogue meter scales.
It can be set within the range of -12 to +12dB.
Table 18.
Source Properties - Audio Tab.
Note:
Neither the A/D nor the 0dB reference adjustments have any effect when digital audio is
used with a digital scale.