background image

 

8

How a fan convector works

 
Hot  water  from  your  central  heating 
system passes through the heat exchanger 
transferring  its  heat  to  the  aluminium 
fins.  Cooler air is drawn in by the fan and 
heated  as  it  passes  over  the  heat 
exchanger  before  being  expelled  gently 
back into the room.  This not only gives a 

more  even  temperature  spread  but  will 
heat  a room up in less than half  the time 
of a traditional steel panel radiator. 
 

 
 
 

 
 

 
 

 
 
 
 
Fan  convectors  include  an  internal  water  temperature  thermostat  that  prevents  the  fan 
from operating until the central heating system water passing through the heat exchanger 
reaches 42ºC.  This prevents cooler air being circulated at start up. 

 

Heating

 - 

see diagram

 

 

Ensure  your  central  heating  system  is 

ON

.  Switch  on  the  heater  (the  neon  switch  will 

illuminate).    Set  the  thermostat  control  (if  fitted)  to  the  desired  temperature.    Set  the 
heat-output  switch  to  medium  output  setting.  Providing  the  water  temperature  in  the 
central  heating system is more than 42ºC  and the  thermostat (if  fitted) is  calling for heat 
the product will switch on.  If you require a faster warm up move the heat output switch to 
boost.    When  the  room  reaches  the  desired  temperature  you  may  move  the  heat-output 
switch to low.   
 

LOW

MEDIUM

BOOST

OFF

ON

 

 
Fault Finding 

This  heater  is  covered  by  a  free  five-year  parts  &  labour  guarantee.    In  the  event  of 
difficulty please contact our After Sales Service on 01245 324560.  It will be helpful if you 
do not disconnect the heater from the central heating system. 

 

Smith's Environmental Products Ltd., 

Blackall Industrial Estate, South Woodham Ferrers, Chelmsford, Essex CM3 5UW 

Tel: 01245 324900 After Sales: 01245 324560 Fax: 01245 324422 

E-mail: [email protected] Web: www.smiths-env.com 

 

In light of our policy of continuous development Smith’s Environmental Products Ltd reserve the right to alter 

specifications without prior notice. 

04-1117  

 

 

 

 

 

 

 

 

 

 

 

Aug 07

 

Summary of Contents for Caspian 60

Page 1: ...gives many years of service In the event of items missing or visible damage please contact our After Sales Service on 01245 324560 We would be most grateful if you would leave this Installation User G...

Page 2: ...al connection should be via a 3A fused spur The fused spur must not be directly above the heater but should be accessible after completion of the installation All heaters must be earthed We recommend...

Page 3: ...the heater pipe work Do not use soldered fittings to the heater pipe work as the heat generated could damage internal wiring and components Note We recommend the use of full flow service valves The v...

Page 4: ...and attach wires to terminals 6 and 7 as diagram below L N E E N L TO FAN FROM MAINS 1 2 3 4 5 6 7 8 L Commissioning 1 Turn on the electrical supply at the fused spur 2 Turn the thermostat control if...

Page 5: ...st setting to be used for faster heat up and the low speed for maintaining temperature Fault Finding 1 Fan does not run on any switch setting a Check the power supply is switched ON b Check fuse in th...

Page 6: ...rs Chelmsford Essex CM3 5UW Tel 01245 324900 After Sales 01245 324560 Fax 01245 324422 E mail info smiths env com Web www smiths env com In light of our policy of continuous development Smith s Enviro...

Page 7: ...and we would be grateful if you complete and return the Guarantee Registration Card to us as soon as possible This will ensure that should you require assistance we can help you quickly and efficient...

Page 8: ...mperature Set the heat output switch to medium output setting Providing the water temperature in the central heating system is more than 42 C and the thermostat if fitted is calling for heat the produ...

Reviews: