background image

 

3

 
2.

 

Fix the product to the wall using appropriate fixings for the wall type.  Refer to the 
diagram & table below for the fixing-hole positions. 

 
  

 

 

3.

 

Connect the heating system flow and return pipes to the heater pipe work.  Do not use 
soldered fittings to the heater pipe work as the heat generated could damage internal 
wiring and components. 

 
Note: We recommend the use of full flow service valves. The valves should be accessible after 
completion of the installation.   
 

4.

 

Check for water leaks. Remove any trapped air from the unit via the built in bleed screw 
located as shown in the diagram below.

 

 
 

 

 

Summary of Contents for Caspian 60

Page 1: ...gives many years of service In the event of items missing or visible damage please contact our After Sales Service on 01245 324560 We would be most grateful if you would leave this Installation User G...

Page 2: ...al connection should be via a 3A fused spur The fused spur must not be directly above the heater but should be accessible after completion of the installation All heaters must be earthed We recommend...

Page 3: ...the heater pipe work Do not use soldered fittings to the heater pipe work as the heat generated could damage internal wiring and components Note We recommend the use of full flow service valves The v...

Page 4: ...and attach wires to terminals 6 and 7 as diagram below L N E E N L TO FAN FROM MAINS 1 2 3 4 5 6 7 8 L Commissioning 1 Turn on the electrical supply at the fused spur 2 Turn the thermostat control if...

Page 5: ...st setting to be used for faster heat up and the low speed for maintaining temperature Fault Finding 1 Fan does not run on any switch setting a Check the power supply is switched ON b Check fuse in th...

Page 6: ...rs Chelmsford Essex CM3 5UW Tel 01245 324900 After Sales 01245 324560 Fax 01245 324422 E mail info smiths env com Web www smiths env com In light of our policy of continuous development Smith s Enviro...

Page 7: ...and we would be grateful if you complete and return the Guarantee Registration Card to us as soon as possible This will ensure that should you require assistance we can help you quickly and efficient...

Page 8: ...mperature Set the heat output switch to medium output setting Providing the water temperature in the central heating system is more than 42 C and the thermostat if fitted is calling for heat the produ...