5.
Isolate the electrical supply and connect the heater electric cable to the fused spur (3
amp). The fused spur must not be directly above the heater and must be accessible after
the installation is complete.
3 AMP FUSED SPUR
6.
Fit a thermostat if required. There is a connection facility within the heater. Remove link
and attach wires to terminals 6 and 7 as diagram below.
L
N
E
E
N
L
TO FAN
FROM MAINS
1
2
3
4
5
6
7
8
L
Commissioning
1.
Turn on the electrical supply at the fused spur
2.
Turn the thermostat control (if fitted) to maximum.
3.
Turn on the central heating system
4.
Turn on the heater – see User Guide.
5.
If these heaters are installed on the same circuit as panel radiators balance the central
heating system
6.
If the installation is working correctly remember to reset the thermostat control (if fitted)
to its normal setting