Dear Customer 

 

We  are  delighted  you  have  chosen  our  products  and  trust  you  are  satisfied  with  the 
installation.  We would ask you to take a few minutes to read through this User Guide.  This 
will help you gain maximum benefit from your heater.   
 
As with all our products your heater is covered by a free five-year parts & labour guarantee 
and we would be grateful if you complete and return the Guarantee Registration Card to us 
as  soon  as  possible.    This  will  ensure  that should  you  require  assistance  we  can  help  you 
quickly and efficiently. 
 
Thank you for your co-operation. 
 
 
 
 
 
 
 
 
Steve Russell 
Customer Service Manager 
01245 324900 

 

Your  fan  convector  is  designed  to  operate  as  part  of  your  central  heating  system  in  the 
same way as a panel radiator.  Providing you leave the heat output switch in either the low, 
medium or boost position it will switch on and off automatically with your central heating 
system.   
 

Summary of Contents for Caspian 60

Page 1: ...gives many years of service In the event of items missing or visible damage please contact our After Sales Service on 01245 324560 We would be most grateful if you would leave this Installation User G...

Page 2: ...al connection should be via a 3A fused spur The fused spur must not be directly above the heater but should be accessible after completion of the installation All heaters must be earthed We recommend...

Page 3: ...the heater pipe work Do not use soldered fittings to the heater pipe work as the heat generated could damage internal wiring and components Note We recommend the use of full flow service valves The v...

Page 4: ...and attach wires to terminals 6 and 7 as diagram below L N E E N L TO FAN FROM MAINS 1 2 3 4 5 6 7 8 L Commissioning 1 Turn on the electrical supply at the fused spur 2 Turn the thermostat control if...

Page 5: ...st setting to be used for faster heat up and the low speed for maintaining temperature Fault Finding 1 Fan does not run on any switch setting a Check the power supply is switched ON b Check fuse in th...

Page 6: ...rs Chelmsford Essex CM3 5UW Tel 01245 324900 After Sales 01245 324560 Fax 01245 324422 E mail info smiths env com Web www smiths env com In light of our policy of continuous development Smith s Enviro...

Page 7: ...and we would be grateful if you complete and return the Guarantee Registration Card to us as soon as possible This will ensure that should you require assistance we can help you quickly and efficient...

Page 8: ...mperature Set the heat output switch to medium output setting Providing the water temperature in the central heating system is more than 42 C and the thermostat if fitted is calling for heat the produ...

Reviews: