Introduction
These heaters are primarily intended for installation directly onto a wall at low level. We
recommend that this heater is stood on the floor and fixed to the wall. They must
not
be
installed in bathrooms or other high humidity areas. Please contact us on 01245 324900 for
details of products suitable for these applications.
These heaters are designed for use on standard two-pipe pumped central heating systems
with a maximum water temperature of 86°C and a maximum pressure of 6 bar (88lbs/in
2
).
Pipes are 22mm depending on model and either pipe may be used as flow or return.
These heaters are classified as a fixed appliance and electrical connection should be via a
3A-fused spur. The fused spur must
not
be directly above the heater but should be
accessible after completion of the installation. All heaters must be earthed.
We recommend the use of full-flow isolating valves. The valves should be accessible after
completion of the installation.
To avoid the possibility of vibration these units must be fitted on a flat even surface.
To conform to Building Regulations Part L (part J in Scotland), a remote room thermostat
can be used in conjunction with this heater. Refer to the instructions supplied with the
thermostat. For further details please contact our Technical Support on 01245 324560.
Please note the guarantee may be invalidated if this product is not installed and used in
accordance with these instructions.
Installation Guide
1.
Remove the front access cover using a small coin